Related Experiment Video
Updated: Feb 12, 2026

Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
Risk Factor Analysis for Capsular Contracture: A 10-Year Sientra Study Using Round, Smooth, and Textured Implants for
M Bradley Calobrace1,2, W Grant Stevens1,2, Peter J Capizzi1,2
1Louisville and Lexington, KY; Marina Del Ray, CA; Charlotte, NC; Santa Monica, CA; and Santa Barbara, CA.
Background:
Despite the increased understanding of surgical best practices, capsular contracture remains the most commonly reported complication and reason for reoperation following breast implant surgery. This study provides a long-term update to a previous investigation of potential contributing risk factors for capsular contracture in primary augmentation patients.
Methods:
The data used for this analysis include 5,122 implants in 2,565 primary augmentation patients implanted by 34 surgeons based on long-term results from Sientra's clinical study. Potential risk factors, including patient and implant attributes, surgery characteristics, pocket irrigation, and postsurgery characteristics, were analyzed using frequency and multivariate models.
Results:
A total of 333 capsular contracture events in 224 patients were reported. The overall Kaplan-Meier rate for capsular contracture was 10.8% by device through 10 years. Results from the multivariate analysis found 8 factors to be independently associated with capsular contracture (implant placement, implant surface, incision site, hematoma or seroma development, device size, surgical bra, steroid, and antibiotic pocket irrigation; all P values < 0.05). Results from correlation analysis found 2 of the 8 factors to be more strongly associated with early onset capsular contracture events, compared with those occurring after 2 and 5 years of implantation (implant surface and steroid pocket irrigation).
Conclusion:
The results of this large-scale, multivariate analysis identified several significant risk factors for capsular contracture, including device features (smooth surface, smaller size), surgical factors (periareolar incision, subglandular placement, antibiotic irrigation), the development of hematoma/seroma, and the use of a surgical bra.
More Related Videos
Related Concept Videos
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Drug Toxicity: Risk factors
Shape and Texture of Coarse Aggregate
Relative Risk
Smooth Endoplasmic Reticulum
The ER provides optimal conditions for synthesizing steroid hormones and lipids, such as phospholipids and triglycerides. Traditionally, lipid metabolism was considered to be a smooth ER function. However, there is no direct evidence to prove that rough ER is completely excluded from lipid...
Functions of Smooth Muscles
Function of visceral smooth muscles
Visceral smooth muscle is found in the walls of all hollow organs, except the heart, and is a key player in the involuntary movements that drive the functioning of these internal organs. This tissue is arranged in...