Related Experiment Video
Updated: Feb 12, 2026

Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
PET Assessment of Epicardial Intimal Disease and Microvascular Dysfunction in Cardiac Allograft Vasculopathy
Sharon Chih1, Aun Yeong Chong2, Fernanda Erthal3
1Heart Failure and Transplantation, Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, Ottawa, Ontario, Canada.
Background:
Cardiac allograft vasculopathy (CAV) is a leading cause of graft failure and death after heart transplantation. Absolute myocardial blood flow (MBF) quantification using rubidium 82 (Rb-82) positron emission tomography (PET) could enable evaluation of diagnostically challenging diffuse epicardial and microvascular disease in CAV.
Objectives:
The authors aimed to evaluate Rb-82 PET detection of CAV.
Methods:
Consecutive transplant recipients undergoing coronary angiography were prospectively evaluated with PET, multivessel intravascular ultrasound (IVUS), and intracoronary hemodynamics. CAV was defined as International Society of Heart and Lung Transplantation CAV1-3 on angiography and maximal intimal thickness ≥0.5 mm on IVUS.
Results:
Forty patients (mean age 56 years, 4.8 years post-transplant) completed evaluation. CAV was detected in 32 patients (80%) by IVUS and 14 (35%) by angiography. PET correlated significantly with invasive coronary flow indices: r = 0.29, rate-pressure product-adjusted myocardial flow reserve (cMFR) versus coronary flow reserve; r = 0.28, relative flow reserve versus fractional flow reserve; and r = 0.37, coronary vascular resistance (CVR) versus index of microcirculatory resistance. Patients with CAV or microvascular dysfunction had reduced cMFR and stress MBF and increased CVR. Receiver operator characteristic curves demonstrated good accuracy of PET for CAV on IVUS (area under the curve 0.77 to 0.81) and optimal diagnostic cutoffs of cMFR <2.9, stress MBF <2.3, and CVR >55. Combined PET assessment for CAV yielded excellent >93% sensitivity (>65% specificity) for 1 abnormal parameter and >96% specificity (>55% sensitivity) for 2 abnormal parameters.
Conclusions:
Rb-82 PET flow quantification has high diagnostic accuracy for CAV, with potential for noninvasive evaluation after heart transplantation.
Related Concept Videos
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...

