Related Experiment Video
Updated: Feb 12, 2026

Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules
Published on: May 23, 2015
Radial EBUS versus CT-guided needle biopsy for evaluation of solitary pulmonary nodules
Wei Wang1,2,3, Like Yu1,2,3, Yuchao Wang1,2,3
1Endoscopic Center of Nanjing Chest Hospital, Nanjing, 210009, Jiangsu, China.
Objective:
This study is aimed to compare the diagnostic yield, complications and influencing factors between Radial endobroncheal ultrasonography guided bronchoscopy(R-EBUS) and CT-guided needle biopsy (CT-PNB), for evaluation of solitary pulmonary nodules(SPNs).
Matrials And Methods:
160 cases of consecutive patients with SPNs were enrolled and divided into R-EBUS and CT-PNB groups randomly. The diagnostic yield, complications and influencing factors between the two groups were evaluated.
Results:
Sensitivity of R-EBUS for malignancy was 73.7% (42/57) and for benign, was 43.5% (10/23), overall diagnostic accuracy was 65% (52/80). In CT-PNB group, overall diagnostic accuracy was 85% (68/80), sensitivity for malignancy was 87.9% (51/58), and for benign was 81.0% (17/21), respectively. Both overall diagnostic yield and incidence of complications in CT-PNB group were higher than those in R-EBUS group (P = 0.006, P = 0.002). In R-EBUS group, the factors affecting diagnostic yield were size (P = 0.027), the distance between SPNs and pleura (P = 0.031) and the location of the probe to lesions (P = 0.009). In CT-PNB group, the distance from the lesions to pleura was correlated with the incidence of pneumothorax (P = 0.001) and pulmonary haemorrhage (P = 0.042). The location of SPNs were adjacent to great vessels was another influencing factor for pulmonary haemorrhage (P = 0.042).
Conclusions:
Both R-EBUS and CT-PNB are valuable tools for diagnosis. SPNs located in medial 1/2 of lung field, or were adjacent to great vessels may be fit for R-EBUS. Those SPNs located in lateral 1/2 of lung field, near to pleura or with less vessels around may be more suitable for CT-PNB.
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...