Recent research on stimulated emission depletion microscopy for reducing photobleaching
1State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China.
Abstract:
Stimulated emission depletion (STED) microscopy is a useful tool in investigation for super-resolution realm. By silencing the peripheral fluorophores of the excited spot, leaving only the very centre zone vigorous for fluorescence, the effective point spread function (PSF) could be immensely squeezed and subcellular structures, such as organelles, become discernable. Nevertheless, because of the low cross-section of stimulated emission and the short fluorescence lifetime, the depletion power density has to be extremely higher than the excitation power density and molecules are exposed in high risk of photobleaching. The existence of photobleaching greatly limits the research of STED in achieving higher resolution and more delicate imaging quality, as well as long-term and dynamic observation. Since the first experimental implementation of STED microscopy, researchers have lift out variety of methods and techniques to alleviate the problem. This paper would present some researches via conventional methods which have been explored and utilised relatively thoroughly, such as fast scanning, time-gating, two-photon excitation (TPE), triplet relaxation (T-Rex) and background suppression. Alternatively, several up-to-date techniques, especially adaptive illumination, would also be unveiled for discussion in this paper. The contrast and discussion of these modalities would play an important role in ameliorating the research of STED microscopy.
Related Concept Videos
Emission Spectra
MOSFET: Depletion Mode
The primary characteristic of depletion-mode MOSFETs is their ability to conduct current between the drain and source terminals without gate bias. This inherent conductivity...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Methods of reducing fever
Pharmacological Methods of Reducing Fever:
Atomic Emission Spectroscopy: Lab