Related Experiment Video
Updated: Feb 12, 2026

Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy
Published on: August 22, 2018
Film-based dose validation of Monte Carlo algorithm for Cyberknife system with a CIRS thorax phantom
Yuxi Pan1, Ruijie Yang1, Jun Li1
1Department of Radiation Oncology, Peking University Third Hospital, Beijing, China.
Abstract:
Monte Carlo (MC) simulation, as the most accurate dose calculation algorithm, is available in the MultiPlan treatment planning system for Cyberknife. The main purpose of this work was to perform experiments to thoroughly investigate the accuracy of the MC dose calculation algorithm. Besides the basic MC beam commissioning, two test scenarios were designed. First, single beam tests were performed with a solid water phantom to verify the MC source model in simple geometry. Then, a lung treatment plan on a CIRS thorax phantom was created to mimic the clinical patient treatment. The plan was optimized and calculated using ray tracing (RT) algorithm and then recalculated using MC algorithm. Measurements were performed in both a homogeneous phantom and a heterogeneous phantom (CIRS). Ion-chamber and radiochromic film were used to obtain absolute point dose and dose distributions. Ion-chamber results showed that the differences between measured and MC calculated dose were within 3% for all tests. On the film measurements, MC calculation results showed good agreements with the measured dose for all single beam tests. As for the lung case, the gamma passing rate between measured and MC calculated dose was 98.31% and 97.28% for homogeneous and heterogeneous situation, respectively, using 3%/2 mm criteria. However, RT algorithm failed with the passing rate of 79.25% (3%/2 mm) for heterogeneous situation. These results demonstrated that MC dose calculation algorithm in the Multiplan system is accurate enough for patient dose calculation. It is strongly recommended to use MC algorithm in heterogeneous media.
Related Concept Videos
Muscles of the Thorax
The diaphragm is at the core of thoracic musculature, the primary muscle involved in breathing. This expansive, dome-shaped muscle marks the division between the thoracic and abdominal cavities. It...
Veins of Thorax
The azygos vein, positioned just right of the midline and anterior to the vertebral column, begins at the junction of the right ascending lumbar and subcostal veins, terminating in the superior vena cava. This vein drains blood from the right side of the thoracic wall, thoracic viscera, and posterior abdominal wall.
The...
Reliability and Validity
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Trial and Error and Algorithm
Data Validation
Key parameters for method validation include:

