Related Experiment Video
Updated: Feb 12, 2026

Generation of Size-controlled Poly ethylene Glycol Diacrylate Droplets via Semi-3-Dimensional Flow Focusing Microfluidic Devices
Published on: July 3, 2018
Poly(ethylene glycol) diacrylate based monolithic capillary columns for the analysis of polar small solutes by
María Vergara-Barberán1, Óscar Mompó-Roselló1, José Manuel Herrero-Martínez1
1Department of Analytical Chemistry, University of Valencia, Burjassot, Spain.
Abstract:
Monolithic stationary phases based on poly(ethylene glycol) diacrylates for capillary electrochromatography were developed. Several poly(ethylene glycol) diacrylates (Mn 250, 575, and 700) were used as single monomers and the resulting columns were carefully compared. Methanol and ethyl ether were selected as porogenic solvents, and in all cases ultraviolet radiation was selected as initiation method to prepare polymeric monoliths. The influence of the monomer chain length and ratio monomer/porogen on the morphological and electrochromatographic properties of the resulting monoliths was investigated. Several families of compounds with different polarity (alkyl benzenes, organophosphorous pesticides, benzoic acid derivatives, and sulfonamides) were selected to evaluate the performance of the fabricated monolithic columns. The best results were obtained for poly(ethylene glycol) diacrylate 700 monoliths affording efficiencies of 144 000 plates/m for retained polar aromatic small molecules and excellent reproducibility in column preparation (RSD values below 2.5%).
Related Concept Videos
Capillary Beds
Capillaries connect arterioles, small branches of arteries, to venules,...
Capillary Exchange
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Capillaries and Their Types
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...