Related Experiment Video
Updated: Feb 12, 2026

Acute Myocardial Infarction in Rats
Published on: February 16, 2011
High sensitive and multiple detection of acute myocardial infarction biomarkers based on a dual-readout
Xiaoqun Gong1, Bo Zhang1, Jiafang Piao1
1School of Life Sciences, Tianjin University, Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology, Collaborative Innovation Center of Chemical Science and Engineering (Tianjin), Tianjin, China.
Immunochromatography test strip (ICTS) displayed high advantages in screening acute myocardial infarction (AMI) biomarkers. However, the low sensitivity and nonquantitative results seriously limited its clinical application. Herein, we designed a highly sensitive, quantitative and dual-readout ICTS for assaying multiple AMI biomarkers based on magnetic nanoparticles (MNPs) quenching the fluorescence of Cy5, which was labeled on capture antibodies on test (T) lines. The changes of fluorescent intensity caused by MNPs nanoprobes enabled us to sensitively quantify cTnI and CK-MB for early diagnosis of AMI in 15 min with a corresponding detection limit of 0.049 ng/mL and 0.085 ng/mL, respectively. Meanwhile, the aggregations of MNPs on T lines allowed colorimetric readout in 2 min for rapid diagnosis of emergent and severe AMI patients. Furthermore, the detection results of 30 clinical serum samples were coincident with those by electrochemiluminescence immunoassay. So this approach is promising a new avenue for clinical diagnosis and prognosis of AMI.
Immunochromatography test strip (ICTS) displayed high advantages in screening acute myocardial infarction (AMI) biomarkers. However, the low sensitivity and nonquantitative results seriously limited its clinical application. Herein, we designed a highly sensitive, quantitative and dual-readout ICTS for assaying multiple AMI biomarkers based on magnetic nanoparticles (MNPs) quenching the fluorescence of Cy5, which was labeled on capture antibodies on test (T) lines. The changes of fluorescent intensity caused by MNPs nanoprobes enabled us to sensitively quantify cTnI and CK-MB for early diagnosis of AMI in 15 min with a corresponding detection limit of 0.049 ng/mL and 0.085 ng/mL, respectively. Meanwhile, the aggregations of MNPs on T lines allowed colorimetric readout in 2 min for rapid diagnosis of emergent and severe AMI patients. Furthermore, the detection results of 30 clinical serum samples were coincident with those by electrochemiluminescence immunoassay. So this approach is promising a new avenue for clinical diagnosis and prognosis of AMI.
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Multiple Allele Traits
Multiple Regression
Farmers can use multiple regression to determine the crop yield based on more than one factor, such as water availability, fertilizer, soil properties, etc. Here, the crop yield is the response or dependent variable as it depends on the other independent variables. The analysis requires the construction of a scatter plot...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Multiple Voltage Sources
In series, the positive terminal of one battery is connected to the negative terminal of another battery. Hence, the voltage of each battery is added to give the net voltage, which is increased because each battery boosts the electrons that enter it. The same current flows through each battery because they are connected in series.
Batteries are...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...

