Related Experiment Video
Updated: Feb 12, 2026

Decomposing the Variance in Reading Comprehension to Reveal the Unique and Common Effects of Language and Decoding
Published on: October 11, 2018
The Impact of Interruptions on Chest Radiograph Interpretation: Effects on Reading Time and Accuracy
Rachel M Wynn1, Jessica L Howe1, Linda C Kelahan2
1MedStar Health, National Center for Human Factors in Healthcare, 3007 Tilden Street, NW, Suite 7L, Washington, DC.
Rationale And Objectives:
The objective of this study was to experimentally test the effect of interruptions on image interpretation by comparing reading time and response accuracy of interrupted case reads to uninterrupted case reads in resident and attending radiologists.
Materials And Methods:
Institutional review board approval was obtained before participant recruitment from an urban academic health-care system during January 2016-March 2016. Eleven resident and 12 attending radiologists examined 30 chest radiographs, rating their confidence regarding the presence or the absence of a pneumothorax. Ten cases were normal (ie, no pneumothorax present), 10 cases had an unsubtle pneumothorax (ie, readily perceivable by a nonexpert), and 10 cases had a subtle pneumothorax. During three reads of each case type, the participants were interrupted with 30 seconds of a secondary task. The total reading time and the accuracy of interrupted and uninterrupted cases were compared. A mixed-factors analysis of variance was run on reading time and accuracy with experience (resident vs attending) as a between-subjects factor and case type (normal, unsubtle, or subtle) and interruption (interruption vs no interruption) as within-subjects factors.
Results:
Interrupted tasks had significantly longer reading times than uninterrupted cases (P = .032). During subtle cases, interruptions reduced accuracy (P = .034), but during normal cases, interruptions increased accuracy (P = .038).
Conclusions:
Interruptions increased reading times and increased the tendency for a radiologist to conclude that a case is normal for both resident and attending radiologists, demonstrating that interruptions reduce efficiency and introduce patient safety concerns during reads of abnormal cases.
More Related Videos
07:22Glycemic Impact on Knee Osteoarthritis Symptoms on Physical, Radiographic, and Inflammatory Markers among Individuals Aged 50 and Over with Diabetes
Published on: March 7, 2025
06:17A Task for Assessing the Impact of a Partner on the Speed and Accuracy of Motor Performance in Rats
Published on: October 17, 2019
Related Concept Videos
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Uncertainty in Measurement: Accuracy and Precision
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Framing Effects
Uncertainty in Measurement: Reading Instruments
Improving Translational Accuracy