Analysis of trace-level nitrated polycyclic aromatic hydrocarbons in water samples by solid-phase microextraction

Jijie Kong1, Mengshu Han1, Ying Liu1

  • 1The State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, China.

Related Concept Videos

Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.9K
Mass Spectrometry: Aromatic Compound Fragmentation01:23

Mass Spectrometry: Aromatic Compound Fragmentation

Upon ionization, aromatic compounds generate a molecular ion that is observed as a prominent peak in their mass spectra. For example, the molecular ion peak for benzene appears at a mass-to-charge ratio of 78, while toluene is observed at a mass-to-charge ratio of 92. The molecular ion benzene is highly stable and does not readily undergo further fragmentation due to the significant amount of energy required to disrupt the aromatic stability of the benzene ring. In contrast, the molecular ion...
2.5K
Gas Chromatography: Sample Injection Systems01:08

Gas Chromatography: Sample Injection Systems

In gas chromatography, the sample is introduced as a vapor plug into the carrier gas stream for high efficiency and resolution. A microsyringe injects the sample solution into a heated sample port, vaporizing it and mixing it with the carrier gas. This process is important to ensure the sample is properly prepared for analysis. Thermally sensitive samples can be injected directly into the column and volatilized by slowly increasing the column temperature.
Two primary injection methods are used...
1.6K
Gas Chromatography: Types of Columns and Stationary Phases01:17

Gas Chromatography: Types of Columns and Stationary Phases

Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
2.5K
Electrophilic Aromatic Substitution: Nitration of Benzene01:20

Electrophilic Aromatic Substitution: Nitration of Benzene

The nitration of benzene is an example of an electrophilic aromatic substitution reaction. It involves the formation of a very powerful electrophile, the nitronium ion, which is linear in shape. The reaction occurs through the interaction of two strong acids, sulfuric and nitric acid.
8.7K
Aromatic Hydrocarbon Anions: Structural Overview01:18

Aromatic Hydrocarbon Anions: Structural Overview

Neutral hydrocarbons like cyclopentadiene with an odd number of carbon atoms and one intervening CH2 group in the ring are not aromatic. Cyclopentadiene with 4 π electrons does not satisfy the 4n + 2 π electron rule. Additionally, the intervening CH2 group is sp3 hybridized and lacks a vacant p orbital, thereby interrupting the overlap of p orbitals in a continuous manner and preventing the delocalization of π electrons throughout the ring.
Due to the absence of continuous...
3.8K