Impact of Cardiac Resynchronization Therapy on Left Ventricular Unloading in Patients with Implanted Left Ventricular
David M Tehrani1, Sirtaz Adatya1, Jonathan Grinstein2
1From the Division of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
Abstract:
Cardiac resynchronization therapy (CRT) and left ventricular assist devices (LVADs) are common heart failure therapies; however, little is known regarding the concomitant use of these devices. We aim to evaluate unloading differences in LVAD patients with and without active biventricular pacing. Left ventricular assist device patients with and without CRT prospectively underwent ramp hemodynamic/echocardiographic testing. Patients with >95% biventricular pacing comprised the active CRT pacing group; all others (no device, implantable cardioverter defibrillator only, CRT without biventricular pacing) were categorized into the non-CRT pacing group. Invasive hemodynamics and echocardiographic characteristics (left ventricular end-diastolic/systolic diameter and valvular regurgitation) were measured at baseline and at incremental speed changes. Unloading slopes were calculated using linear regression modeling for individual hemodynamics and echocardiographic characteristics across speeds. Among 62 LVAD patients (age 59.6 ± 11.4 years, 60% male), 25 had active CRT pacing. There was no significant difference in echocardiographic or hemodynamic characteristics at baseline or final set speeds between CRT groups. Similarly, no significant differences were noted in the unloading characteristics. In LVAD patients, active biventricular pacing is unlikely to improve echocardiographic or hemodynamic characteristics.
More Related Videos
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Impact of Groups on Groups
Impact
When particles with different initial velocities collide, they induce deformation by applying equal and opposite impulses. At the point of maximum deformation, the particles move together with...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Gene Therapy