Related Experiment Video
Updated: Feb 12, 2026

Comparison of Three Different Methods for Determining Cell Proliferation in Breast Cancer Cell Lines
Published on: September 3, 2016
Determination of Prostate Volume: A Comparison of Contemporary Methods
Adam Bezinque1, Andrew Moriarity2, Crystal Farrell3
1Michigan State University College of Osteopathic Medicine, East Lansing, Michigan.
Rationale And Objectives:
Prostate volume (PV) determination provides important clinical information. We compared PVs determined by digital rectal examination (DRE), transrectal ultrasound (TRUS), magnetic resonance imaging (MRI) with or without three-dimensional (3D) segmentation software, and surgical prostatectomy weight (SPW) and volume (SPV).
Materials And Methods:
This retrospective review from 2010 to 2016 included patients who underwent radical prostatectomy ≤1 year after multiparametric prostate MRI. PVs from DRE and TRUS were obtained from urology clinic notes. MRI-based PVs were calculated using bullet and ellipsoid formulas, automated 3D segmentation software (MRI-A3D), manual segmentation by a radiologist (MRI-R3D), and a third-year medical student (MRI-S3D). SPW and SPV were derived from pathology reports. Intraclass correlation coefficients compared the relative accuracy of each volume measurement.
Results:
Ninety-nine patients were analyzed. Median PVs were DRE 35 mL, TRUS 35 mL, MRI-bullet 49 mL, MRI-ellipsoid 39 mL, MRI-A3D 37 mL, MRI-R3D 36 mL, MRI-S3D 36 mL, SPW 54 mL, SPV-bullet 47 mL, and SPV-ellipsoid 37 mL. SPW and bullet formulas had consistently large PV, and formula-based PV had a wider spread than PV based on segmentation. Compared to MRI-R3D, the intraclass correlation coefficient was 0.91 for MRI-S3D, 0.90 for MRI-ellipsoid, 0.73 for SPV-ellipsoid, 0.72 for MRI-bullet, 0.71 for TRUS, 0.70 for SPW, 0.66 for SPV-bullet, 0.38 for MRI-A3D, and 0.33 for DRE.
Conclusions:
With MRI-R3D measurement as the reference, the most reliable methods for PV estimation were MRI-S3D and MRI-ellipsoid formula. Automated segmentations must be individually assessed for accuracy, as they are not always truly representative of the prostate anatomy. Manual segmentation of the prostate does not require expert training.
More Related Videos
08:38Renal Capsule Xenografting and Subcutaneous Pellet Implantation for the Evaluation of Prostate Carcinogenesis and Benign Prostatic Hyperplasia
Published on: August 28, 2013
05:35Transperineal Prostate Biopsy Using a Cone-shaped Double-hole Method with Dual-plane Probe Guidance
Published on: June 6, 2025
Related Concept Videos
Contemporary Psychology
Biopsychology
Biopsychology, also known as biological psychology or behavioral neuroscience, focuses on the biological underpinnings of behavior and mental processes. It...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Molecular Comparison of Gases, Liquids, and Solids
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Constant Volume Calorimetry