Hemodynamic Effects of Valve Asymmetry in Sapien 3 Transcatheter Aortic Valves
Daniel R Mangels, Mary Siki, Rohan Menon
1University of Pennsylvania, PCAM South Pavilion 11-107, 3400 Civic Center Blvd, Philadelphia, PA 19104 USA. Howard.herrmann@uphs.upenn.edu.
Background:
Eccentric valve deployment after transcatheter aortic valve replacement (TAVR) has been associated with abnormal leaflet shear stresses that may accelerate structural valve deterioration (SVD). This phenomenon has not been studied in patients receiving Sapien 3 prostheses (Edwards Lifesciences).
Methods:
A retrospective cohort analysis of 100 patients who received Sapien 3 valves between 2013 and 2015 at a single institution was performed. Axial fluoroscopic images from the co-planar view were used to assess TAVR asymmetry, which was defined as a ratio of left-to-right valve heights ≤0.9 or ≥1.1. Transthoracic echocardiograms (TTEs) were obtained at follow-up to analyze peak and mean aortic valve (AV) gradients, paravalvular leak (PVL), and aortic insufficiency (AI).
Results:
Overall, 26 mm and 29 mm valves had greater asymmetry (45.2% and 46.9%) compared to 23 mm valves (21.2%; P=.06). There was no relationship between pre-TAVR eccentricity and post-TAVR asymmetry, but greater annular calcification was associated with a higher incidence of TAVR asymmetry. Although asymmetry was associated with higher mean and peak AV gradients among 23 mm and 26 mm valves at both 1-year and 2-year follow-up exams, these results did not reach significance. There were no significant differences in PVL or AI severity between asymmetric and symmetric valves.
Conclusions:
Asymmetric deployment of Sapien 3 valves is common, particularly among 26 mm and 29 mm prostheses. Overall, we detected a small increase in gradients in smaller prostheses, which could reflect early subclinical SVD. Longer follow-up will be necessary to determine the extent to which eccentricity is associated with clinically significant SVD.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Membrane Asymmetry Regulating Transporters
Flippase
Eukaryotic flippases are type-IV P-type ATPases or P4-ATPases belonging to P-type ATPase family proteins that are membrane-bound pumps involved in the ATP-mediated transport of ions and molecules across the membrane. Flippases flip specific phospholipids from the outer to the inner leaflet of a membrane. All P4-ATPases have one...
Aortic Regurgitation I: Introduction