Related Experiment Video
Updated: Feb 12, 2026

06:02
2-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
10.9K
Evaluation of Maximum Bite Force in Patients with Complete Dentures
Kujtim Shala1, Arlinda Tmava-Dragusha1, Linda Dula1
1Department of Prosthetic Dentistry, Faculty of Medicine, School of Dentistry, Prishtina, Kosovo.
Open Access Macedonian Journal of Medical Sciences
|April 4, 2018
Summary
Maximum bite force (mBF) increased over time for new complete denture wearers, especially on the dominant side. This indicates improved functional adaptation with experience.
Area of Science:
- Dentistry and Oral Health
- Biomechanical Engineering
- Prosthodontics
Background:
- Complete denture wearers (CDWs) often experience adaptation challenges.
- Assessing functional adaptation is crucial for denture success.
Purpose of the Study:
- To evaluate maximum bite forces (mBF) on dominant (DS) and non-dominant sides (NDS) after new complete denture insertion.
- To determine the influence of prior experience and gender on mBF.
- To identify mBF as a variable for functional adaptation assessment.
Main Methods:
- 88 complete denture wearers (CDWs) participated.
- Maximum bite force (mBF) measured using a piezoelectric gnathodynamometer.
- Data analyzed using One Way Repeated Measurement of ANOVA.
Main Results:
- Average mBF increased over the observation period on both DS and NDS.
- Significant increases in mBF were observed on the DS (p=0.0001) compared to NDS (p=0.047).
- Prior experience significantly influenced mBF on both sides.
Conclusions:
- Maximum bite force (mBF) is a significant indicator of functional adaptation in new complete denture wearers.
- mBF measurements can help assess the effectiveness of denture adaptation over time.
Related Concept Videos
Maximum Deflection
1.1K
When analyzing beams under unsymmetrical loads, such as a train moving on a bridge, it is crucial to accurately determine the points of maximum stress and deflection. The process involves identifying the maximum deflection of the beam, which may not always occur at its midpoint due to the uneven distribution of the load.
The maximum deflection occurs at a specific point, known as point O, where the tangent to the deflection curve is horizontal. To find point O, the slope of the tangent at any...
The maximum deflection occurs at a specific point, known as point O, where the tangent to the deflection curve is horizontal. To find point O, the slope of the tangent at any...
1.1K
Maximum Power Transfer
950
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
950
Maximum Size of Aggregate
569
The maximum size of aggregate is defined as the aperture of the sieve retaining 15 percent or more of the particles present in the aggregate sample. The aggregate's maximum size impacts the concrete's water requirement, workability, and strength. Larger aggregates reduce the surface area needing cement paste coverage, which can lower water needs, thereby allowing a decrease in the water-to-cement ratio when the desired workability and richness of the mix are to be maintained, which can...
569
The Maximum Power Transfer Theorem
1.2K
Consider a linear AC Thevenin equivalent circuit connected to a load impedance.
The load connected draws the current, and the circuit delivers the power to the load. The alternating current flowing through the load is determined using the rectangular form of voltages, currents, network impedance, and load impedance. The average power delivered to the load is obtained from the product of the square of current and load resistance.
The load connected draws the current, and the circuit delivers the power to the load. The alternating current flowing through the load is determined using the rectangular form of voltages, currents, network impedance, and load impedance. The average power delivered to the load is obtained from the product of the square of current and load resistance.
1.2K
Maximum Power Flow and Line Loadability
626
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
626
Intermolecular Forces
72.0K
Atoms and molecules interact through bonds (or forces): intramolecular and intermolecular. The forces are electrostatic as they arise from interactions (attractive or repulsive) between charged species (permanent, partial, or temporary charges) and exist with varying strengths between ions, polar, nonpolar, and neutral molecules. The different types of intermolecular forces are ion–dipole, dipole–dipole, hydrogen bonds, and dispersion; among these, dipole–dipole, hydrogen...
72.0K