Related Experiment Video
Updated: Feb 12, 2026

Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution
Published on: August 16, 2012
Scleral Buckling under a Slit-lamp Illumination System with a Contact Wide-angle Viewing Lens Compared with an
Seung Yong Choi1, Youlim Lee1, Mirinae Kim1
1Department of Ophthalmology and Visual Science, The Catholic University of Korea College of Medicine, Seoul, Korea.
Purpose:
To investigate the outcomes of scleral buckling surgery performed under a slit-lamp illumination system (Visulux) with a contact wide-angle viewing lens (Mini Quad) in patients with rhegmatogenous retinal detachment (RRD) and to compare these outcomes with those of surgery performed under an indirect ophthalmoscope.
Methods:
By retrospective review of electronic medical records, patients with RRD who had undergone scleral buckling surgery were identified. Scleral buckling surgeries were performed with two illumination instruments, a slit-lamp (SL group) and an indirect ophthalmoscope (IO group). Subretinal fluid drainage, cryopexy, and intravitreal gas injection were performed optionally. At 6 months after surgery, anatomical and functional outcomes were evaluated and compared between the two groups. Operation time was also compared between the two groups.
Results:
Of the 45 total patients (45 eyes), 28 were included in the SL group, and 17 were included in the IO group. In the SL and IO groups, the primary anatomical success rate was 89.3% and 88.2%, respectively (p = 0.92). The logarithm of the minimal angle of resolution change, which reflects improvement in best-corrected visual acuity after surgery, was -0.19 ± 0.38 in the SL group and -0.21 ± 0.63 in the IO group; this difference was not statistically significant (p = 0.91). The mean operation time was significantly shorter in the SL group (78.9 ± 11.8 minutes) than in the IO group (100.0 ± 13.9 minutes, p < 0.001), especially for patients who underwent additional procedures such as subretinal fluid drainage and cryopexy (81.4 ± 12.9 and 103.5 ± 12.3 minutes, respectively, p < 0.001).
Conclusions:
Scleral buckling surgery performed under a slit-lamp illumination system yielded a similar anatomical success rate and similar functional improvement in RRD compared with surgery performed under an indirect ophthalmoscope. The slit-lamp system could save time, especially in bullous RRD, which requires additional subretinal fluid drainage.
Related Concept Videos
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Indirect Motor Pathways
The vestibulospinal tract originates in the vestibular nuclei of the brainstem. The vestibular system detects changes in...
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Econometric Views (EViews)
Cranial Bones: Lateral View
The temporal bone forms the lower lateral side of the skull. The temporal bone is subdivided into several regions. The flattened upper portion is the squamous portion of the temporal bone. Below this area and projecting anteriorly is the zygomatic process of the temporal bone, which forms the posterior portion of the zygomatic arch. Posteriorly is the mastoid portion of the temporal bone. Projecting...
EDTA: Indirect and Alkalimetric Titration

