Related Experiment Video
Updated: Feb 12, 2026

Optogenetic Phase Transition of TDP-43 in Spinal Motor Neurons of Zebrafish Larvae
Published on: February 25, 2022
Endolysosomal pathway activity protects cells from neurotoxic TDP-43
Christine Leibiger1, Jana Deisel1, Andreas Aufschnaiter2
1Institute of Cell Biology, University of Bayreuth, Universitätsstraße 30, 95447 Bayreuth, Germany.
None:
The accumulation of protein aggregates in neurons is a typical pathological hallmark of the motor neuron disease amyotrophic lateral sclerosis (ALS) and of frontotemporal dementia (FTD). In many cases, these aggregates are composed of the 43 kDa TAR DNA-binding protein (TDP 43). Using a yeast model for TDP 43 proteinopathies, we observed that the vacuole (the yeast equivalent of lysosomes) markedly contributed to the degradation of TDP 43. This clearance occurred via TDP 43-containing vesicles fusing with the vacuole through the concerted action of the endosomal-vacuolar (or endolysosomal) pathway and autophagy. In line with its dominant role in the clearance of TDP 43, endosomal-vacuolar pathway activity protected cells from the detrimental effects of TDP 43. In contrast, enhanced autophagy contributed to TDP 43 cytotoxicity, despite being involved in TDP 43 degradation. TDP 43's interference with endosomal-vacuolar pathway activity may have two deleterious consequences. First, it interferes with its own degradation via this pathway, resulting in TDP 43 accumulation. Second, it affects vacuolar proteolytic activity, which requires endosomal-vacuolar trafficking. We speculate that the latter contributes to aberrant autophagy. In sum, we propose that ameliorating endolysosomal pathway activity enhances cell survival in TDP 43-associated diseases.
More Related Videos
Related Concept Videos
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protecting Self-Esteem
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...

