Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Correct Assessment of Acetabular Component Orientation in Total Hip Arthroplasty From Plane Radiographs
Diana Widmer1, Kilian Reising2, Elmar Kotter3
1Department of Orthopedic Surgery and Traumatology, University Hospital Freiburg, Freiburg, Germany; Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Background:
Correct positioning of the cup is an important factor in total hip arthroplasty. Assessing its position from a plain anteroposterior pelvic radiograph is known to be hampered by systemic errors. This study focuses on developing a correction method to adjust for these potential sources of error and to eliminate them based on a 3D geometric analysis.
Methods:
Computed tomography scans of 113 (66 male, 47 female) pelvices were reconstructed and virtually projected onto a plain radiograph with varying rotational and translational positions. Thus cup inclination and anteversion as measured on a 2D-radiograph and in the 3D environment were correlated. Projected offset of the symphysis from the mid-sacrum served as a mean to measure pelvic right/left-rotation. Pelvic tilt was determined from the projected height of the contour of the small pelvis. Correction formulas were verified by projecting a gimbal-mounted artificial pelvis with a cup implanted in a known position.
Results:
We found gender-specific formulas that correct for malrotated and off-centered radiographs. Applying these formulas cup inclination was assessed as close as 1.3° (±1.90°) to the true 3D value and cup anteversion as close as 1° (±1.91°) although deviations between directly measured plain values and corrected values rose up to 18°.
Conclusion:
Inherent effects of central projection and malrotations due to pelvic tilt, pelvic rotation, and noncentered radiographs are corrected. Evaluation of radiographic inclination and anteversion of acetabular cups from plain 2D-radiographs show improved precision. Real values are approached better than 1.3° when applying our correction formulas.
Related Concept Videos
Distance Corrections
Power Factor Correction
Work Done Over an Inclined Plane
The work done by gravity to move a rigid body, or the work done by an opposing force to move a rigid body against gravity, can be calculated using the center-of-mass framework. It is the line integral of the force of gravity over the path, considered positive if...
Location and Orientation of the Heart
Coordinate Plane
Body Planes
The sagittal plane is the plane that divides the body or an organ vertically into right and left sides. If this vertical plane runs directly down the middle of the body resulting in equal division, it is called the midsagittal or median...