Related Experiment Video
Updated: Feb 12, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry (SURD-IR): early results from 3343
Marco Di Eusanio1,2, Kevin Phan2, Paolo Berretta1
1Cardiovascular Department, Cardiac Surgery Unit, Ospedali Riuniti, Polytechnic University of Marche, Ancona, Italy.
Objectives:
The Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry (SURD-IR) was established by a consortium of 18 research centres-the International Valvular Surgery Study Group (IVSSG)-to overcome limitations of the literature and provide adequately powered evidence on sutureless and rapid-deployment aortic valves replacement (SURD-AVR).
Methods:
Data from 3343 patients undergoing SURD-AVR over a 10-year period (2007-2017) were collected in the registry. The mean age of the patients was 76.8 ± 6.7 years, with 36.4% being 80 years or older. The average logistic EuroSCORE was 11.3 ± 9.7%.
Results:
Isolated SURD-AVR was performed in 70.7% (n = 2362) of patients using full sternotomy (35.3%) or less invasive approaches (64.8%). Overall hospital mortality was 2.1%, being 1.4% in patients who had isolated SURD-AVR and 3.5% in those who had concomitant procedures (P < 0.001). When considering baseline risk profile, mortality rate was 0.8% and 1.9% in low risk (logistic EuroSCORE <10%) isolated SURD-AVR and combined SURD-AVR, respectively, and 2.2% and 3.7% in higher risk patients (logistic EuroSCORE ≥10%). Postoperative neurological complications included stroke (2.8%) and transient ischaemic attack (1.1%). New atrioventricular block requiring pacemaker occurred in 10.4% of the patients. The rate of pacemaker implantation significantly decreased over time [from 17.2% (2007-2008) to 5.4% (2016); P = 0.02].
Conclusions:
Our findings showed that SURD-AVR is a safe and effective alternative to conventional aortic valve replacement and is associated with excellent clinical outcomes. Further adequately powered statistical analyses from the retrospective and prospective SURD-IR will allow for the development of high-quality evidence-based clinical guidelines for SURD-AVR.
More Related Videos
Related Concept Videos
Internal Energy
Internal Energy
Internal Receptors
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Continuous Renal Replacement Therapy
International System of Units
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...

