Robotic mitral valve replacements with bioprosthetic valves in 52 patients: experience from a tertiary referral
Chia-Cheng Kuo1,2,3, Hsiao-Huang Chang2,4, Chung-Hsi Hsing5,6
1Division of Cardiovascular Surgery, Department of Surgery, Chi Mei Medical Center, Tainan, Taiwan.
Objectives:
Robotic mitral valve replacement (MVR) emerged in the late 1990s as an alternative approach to conventional sternotomy. With the increased use of bioprosthetic valves worldwide and strong patient desire for minimally invasive procedures, the safety and feasibility of robotic MVRs with bioprosthetic valves require investigation.
Methods:
Between January 2013 and May 2017, 52 consecutive patients underwent robotic MVRs using the da Vinci Si surgical system (Intuitive Surgical Inc., Sunnyvale, CA, USA). Their mean age was 55.1 ± 13.8 years, and mean EuroSCORE II was 2.25% ± 1.25%. Among the enrolled patients, 32 (61.5%) patients presented with preoperative atrial fibrillation, 6 (11.5%) patients had experienced embolic stroke and 5 (9.6%) patients had undergone previous cardiac surgery. The operations were performed using cardiopulmonary bypass (CPB) under an arrested heart status.
Results:
Five porcine valves and 47 bovine valves were implanted. A total of 38 (73.1%) patients received concomitant cardiac procedures, including 26 Cox-maze IV procedures, 12 tricuspid valve repairs and 5 atrial septal defect repairs. The mean aortic cross-clamp and CPB times were 141.3 ± 34.3 min and 217.1 ± 42.0 min, respectively. There was no operative mortality. During the mean follow-up of 29 ± 15 months, no prosthesis degeneration was noted. The average left atrial dimension exhibited a significant decrease from 51.4 ± 11.5 mm to 42.6 ± 10.1 mm.
Conclusions:
Robotic MVR with bioprosthetic valves is safe, feasible and reproducible. Mid-term results are encouraging. Both aortic cross-clamp and CPB times can be improved with experience.
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...