Cyclic voltammetric studies of Gemifloxacin using Gold electrode in presence of Britton-Robinson Buffer

S Azhar Ali1, Atya Hassan2, Mahboob Muhammad3

  • 1Department of Chemistry, University of Karachi, Karachi, Pakistan.

Related Concept Videos

Voltammetric Techniques: Cyclic Voltammetry01:10

Voltammetric Techniques: Cyclic Voltammetry

Cyclic voltammetry (CV) is an electrochemical technique used to investigate the redox properties of a chemical species. It involves measuring the current response of an electrochemical cell as a function of the applied potential. The setup for cyclic voltammetry typically consists of a working electrode, a reference electrode, and a counter electrode—all immersed in an electrolyte solution. The working electrode is where the redox reaction of interest occurs, while the reference electrode...
1.6K
Buffers02:56

Buffers

A solution containing appreciable amounts of a weak conjugate acid-base pair is called a buffer solution, or a buffer. Buffer solutions resist a change in pH when small amounts of a strong acid or a strong base are added. A solution of acetic acid and sodium acetate is an example of a buffer that consists of a weak acid and its salt: CH3COOH (aq) + CH3COONa (aq). An example of a buffer that consists of a weak base and its salt is a solution of ammonia and ammonium chloride: NH3 (aq) + NH4Cl...
173.3K
Buffers: Buffer Capacity01:09

Buffers: Buffer Capacity

Buffer capacity is the quantitative measure of a buffer to resist the change in pH. As shown in the following equation, the buffer capacity, denoted by 'beta', is expressed as the number of moles of acid or base needed to change the pH of a one-liter buffer solution by 1 unit. Here, Ca and Cb indicate the number of moles of acid and base, respectively. Note that dpH represents the change in pH.
In the graph, pH is plotted as a function of the number of moles of base (Cb) added to a weak...
2.5K
Buffer Effectiveness02:19

Buffer Effectiveness

Buffer solutions do not have an unlimited capacity to keep the pH relatively constant . Instead, the ability of a buffer solution to resist changes in pH relies on the presence of appreciable amounts of its conjugate weak acid-base pair. When enough strong acid or base is added to substantially lower the concentration of either member of the buffer pair, the buffering action within the solution is compromised.
The buffer capacity is the amount of acid or base that can be added to a given volume...
55.6K
Voltammetric Techniques: Pulse Voltammetry01:17

Voltammetric Techniques: Pulse Voltammetry

Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
1.6K
Calculating pH Changes in a Buffer Solution02:45

Calculating pH Changes in a Buffer Solution

A buffer can prevent a sudden drop or increase in the pH of a solution after the addition of a strong acid or base up to its buffering capacity; however, such addition of a strong acid or base does result in the slight pH change of the solution. The small pH change can be calculated by determining the resulting change in the concentration of buffer components, i.e., a weak acid and its conjugate base or vice versa. The concentrations obtained using these stoichiometric calculations can be used...
58.9K