Relationships between patient characteristics and contrast agent dose for successful computed tomography venography
Yuji Iyama1, Takeshi Nakaura, Masafumi Kidoh
1Department of Diagnostic Radiology, Kumamoto chuo hospital Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.
Abstract:
The aim of this study was to evaluate the effect of patient characteristics on the contrast agent dosage that is required to reach effective enhancement of the inferior vena cava (IVC) on computed tomography venographs (CTV).This retrospective study included 50 patients who underwent CTV at 80 kVp. The contrast injection protocol (iodine 600 mg/kg) was tailored to their body weight. We calculated the required contrast agent volume (CAVmean-IVC) to reach the mean enhancement of IVC. We performed univariate and multivariate linear regression analyses between the sex, age, body weight (BW), lean body weight (LBW), body surface area (BSA), height (HT), estimated glomerular filtration rate (eGFR), and CAVmean-IVC.The univariate linear regression analysis show that HT, BW, LBW, and BSA were significantly correlated with CAVmean-IVC (P < .01 for all). The CAVmean-IVC was significantly higher for males than females (P < .01). Multivariate regression analysis showed that BW, LBW, and BSA had a statistically significant effect on CAVmean-IVC. There was no significant correlation of age, HT, or eGFR with CAVmean-IVC.BW, LBW, and BSA each had an independent significant effect on CAVmean-IVC. The conventional BW-tailored contrast injection protocol might be insufficient for CTV.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Dose-Response Relationship: Overview
Dose-Response Relationship: Potency and Efficacy
Dose-Response Relationship: Selectivity and Specificity
Drug Dosing: Geriatric Patients