Related Experiment Video
Updated: Feb 12, 2026

A Novel Method for Involving Women of Color at High Risk for Preterm Birth in Research Priority Setting
Published on: January 12, 2018
The birth canal: correlation between the pubic arch angle, the interspinous diameter, and the obstetrical conjugate:
Sharon Perlman1,2, Lisa Raviv-Zilka2,3, Denis Levinsky1
1a Prenatal Diagnostic Unit, Department of Obstetrics and Gynecology, The Chaim Sheba Medical Center , Tel HaShomer , Israel.
Abstract:
Background: Assessment of pelvic configuration is an important factor in the prediction of a successful vaginal birth. However, manual evaluation of the pelvis is practically a vanishing art, and imaging techniques are not available as a real-time bed-side tool. Unlike the obstetrical conjugate diameter (OC) and inter spinous diameter (ISD), the pubic arch angle (PAA) can be easily measured by transperineal ultrasound. Objectives: Three-dimensional computed tomography bone reconstructions were used to measure the three main birth canal diameters, evaluate the correlation between them, and establish the normal reference range for the inlet, mid-, and pelvic outlet. Study design: Measurements of the PAA, obstetric conjugate (OC), and ISD were performed offline using three-dimensional post processing reconstruction in bone algorithm application of the pelvis on examinations performed for suspected renal colic in nonpregnant reproductive age woman. The mean of two measurements was used for statistical analysis which included reproducibility of measurements, regression curve estimation between PAA, OC, and ISD, and calculation of the respective reference range centiles for each PAA degree. Results: Two hundred ninety-eight women comprised the study group. The mean ± SD of the PAA, ISD, and OC were 104.9° (±7.4), 103.8 mm (±7.3), and 129.9 mm (±8.3), respectively. The intra- and interobserver agreement defined by the intraclass correlation coefficient (ICC) was excellent for all parameters (range 0.905-0.993). A significant positive correlation was found between PAA and ISD and between PAA and OCD (Pearson's correlation = 0.373 (p < .001), and 0.163 (p = .022), respectively). The best regression formula was found with quadratic regression for inter spinous diameter (ISD): 34.122778 + (0.962182*PAA - 0.002830*PAA2), and linear regression for obstetric conjugate (OC): 110.638397 + 0.183156*PAA. Modeled mean, SD, and reference centiles of the ISD and OCD were calculated using the above regression models as function of the PAA. Conclusions: We report significant correlation between the three pelvic landmarks with greatest impact on the prediction of a successful vaginal delivery: the PAA which is easily measured sonographically and the ISD and OC which are not measurable by ultrasound. This correlation may serve as a basis for future studies to assess its utility and prognostic value for a safe vaginal delivery.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Design Example: Traverse Angle Computations
Reproductive Cloning
Somatic Cell Nuclear Transfer
In SCNT, an egg cell is taken from an animal and its nucleus is removed, creating an enucleated egg. Then a somatic...
Birth Control Methods
The Arch of Aorta
Encircling the heart, the coronary arteries form a ring-like structure before...

