Related Experiment Video
Updated: Feb 12, 2026

Author Spotlight: Utilizing Venoplasty Balloon Model in Rodents to Simulate Surgical Interventions for Deep Veins
Published on: May 24, 2024
The inferior vena cava diameter is a useful ultrasound finding for predicting postpartum blood loss
Tomohiro Oba1, Maya Koyano1, Junichi Hasegawa1,2
1a Department of Obstetrics and Gynecology , Showa University School of Medicine , Tokyo , Japan.
Purpose: To assess whether the ultrasonographic measurement of the inferior vena cava (IVC) diameter in postpartum women is a useful parameter in evaluating the actual blood loss during delivery due to massive postpartum hemorrhage. Materials and methods: In postpartum women with blood loss ≥500 g, abdominal ultrasonography was performed 1 hour after delivery. The IVC diameter was measured during inspiration (IVCi) and expiration (IVCe). The maternal heart rate, blood pressure, and shock index (heart rate/systolic blood pressure) were also measured. The predictive value of these parameters for severe anemia (hemoglobin <7.0 g/dL) a day after delivery was evaluated via receiver operating characteristic (ROC) analyses. Results: Seven patients with severe anemia and 77 controls were included in the analysis. The area under the curve (AUC) for IVCi (0.905) and IVCe (0.926) was higher than that for the shock index (0.890), heart rate (0.874), or systolic blood pressure (0.752). Among the examined parameters, the best sensitivity was achieved by IVCe and systolic blood pressure (71.4%). Conclusions: The ultrasonographic measurement of the IVC diameter was found to be the most useful parameter in evaluating the actual maternal blood loss after delivery.
Purpose: To assess whether the ultrasonographic measurement of the inferior vena cava (IVC) diameter in postpartum women is a useful parameter in evaluating the actual blood loss during delivery due to massive postpartum hemorrhage. Materials and methods: In postpartum women with blood loss ≥500 g, abdominal ultrasonography was performed 1 hour after delivery. The IVC diameter was measured during inspiration (IVCi) and expiration (IVCe). The maternal heart rate, blood pressure, and shock index (heart rate/systolic blood pressure) were also measured. The predictive value of these parameters for severe anemia (hemoglobin <7.0 g/dL) a day after delivery was evaluated via receiver operating characteristic (ROC) analyses. Results: Seven patients with severe anemia and 77 controls were included in the analysis. The area under the curve (AUC) for IVCi (0.905) and IVCe (0.926) was higher than that for the shock index (0.890), heart rate (0.874), or systolic blood pressure (0.752). Among the examined parameters, the best sensitivity was achieved by IVCe and systolic blood pressure (71.4%). Conclusions: The ultrasonographic measurement of the IVC diameter was found to be the most useful parameter in evaluating the actual maternal blood loss after delivery.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Predicting Molecular Geometry
Finding the Center of Gravity
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection

