Echocardiographic predictors of atrial fibrillation after mitral valve replacement
Al-Shimaa Mohamed Sabry1, Heba Abd El-Kader Mansour1, Tarek Helmy Abo El-Azm1
1Cardiology Department, Faculty of Medicine, Benha University, Egypt.
Objectives:
Detection of the echocardiographic predictors of post-operative atrial fibrillation in patients with rheumatic mitral valve disease undergoing mitral valve replacement.
Methods:
The study included 50 patients with rheumatic mitral valve disease undergoing mitral valve replacement. Preoperative assessment included standard two-dimensional echocardiography to assess LA diameter, volume, and emptying fraction, LV volume and ejection fraction. TDI derived velocity, strain of the left atrium and speckle tracking to assess left ventricular function then postoperative follow up for 1 month for occurrence of atrial fibrillation.
Results:
The incidence of postoperative AF was 44%; these patients were significantly older (P = 0.001) and show higher prevalence of DM (P = 0.001) and HTN (P = 0.001). Also, LA diameters (antero-posterior, transverse and longitudinal) and LA volumes (maximal and minimal) were increased (P < 0.001), but no difference in LA emptying fraction (P > 0.05). Systolic LA strain and left ventricular global longitudinal strain were significantly reduced in those patients (P value <0.001). Echocardiographic predictors of AF were LA systolic strain (P value <0.001) and LV global longitudinal strain (P value = 0.003). Cutoff value for systolic LA strain ≤23 had sensitivity 90.91% and specificity 93.33% in predicting POAF. While, left ventricular global longitudinal strain ≤-14.9% had sensitivity 63.6% and specificity 100.0% in predicting AF.
Conclusion:
LA systolic strain and LV global longitudinal strain were significant predictors of POAF. Echocardiographic parameters can identify patients at greater risk of developing POAF who can benefit from preventive measure and guide the selection of prosthesis.
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...