Sleep apnea detection by a cardiac resynchronization device integrated thoracic impedance sensor: A validation study
Fabian Barbieri1, Wolfgang Dichtl1, Anna Heidbreder2,3
1University Hospital for Internal Medicine III (Cardiology and Angiology), Medical University Innsbruck, Austria.
Background:
Sleep disordered breathing is a common but often undiagnosed comorbidity in heart failure patients. Cardiac implantable electronic devices used for cardiac resynchronization therapy (CRT) may detect sleep apnea by use of a transthoracic impedance sensor. Validation of the AP scan® algorithm (Boston Scientific®) was performed by using the diagnostic gold standard polysomnography (PSG).
Methods:
Forty-one patients with impaired left ventricular ejection fraction, frequent right ventricular pacing due to atrioventricular block and heart failure symptoms despite optimal medical therapy underwent upgrading to biventricular pacing. Within one month after left ventricular lead implantation, sleep apnea was assessed by single-night PSG and AP scan® measurements.
Results:
AP scan® measurements were valid in only 21 of 41 (51.2%) patients in the index night of the PSG. The PSG determined apnea-hypopnea index did not correlate statistically significant with the AP scan® measurements (r = 0.41, 95% confidence interval -0.05-0.72, p = 0.07). The degree of overestimation is displayed by using the Bland-Altman method: mean difference -12.4, standard deviation ± 15.8, 95% confidence interval -43.3-18.6.
Conclusions:
In heart failure patients receiving CRT upgrading, the AP scan® algorithm may need further improvement before it can be recommended for sleep apnea detection.
More Related Videos
04:33Author Spotlight: Unveiling the Connection Between Sleep Disorders and Cognitive Symptoms in Depression
Published on: April 26, 2024
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Reliability and Validity
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Thoracic Aorta
Impedance Combination
The Thoracic Cage: Sternum
The sternum is the elongated bony structure on the anterior side of the thoracic cage. It consists of three parts: the manubrium, the body, and the xiphoid...