Related Experiment Video
Updated: Feb 12, 2026

09:20
Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
Published on: February 13, 2021
7.1K
Beyond left ventricular ejection fraction there is a right heart that pumps: reply
Lucas N L Van Aelst1,2,3, Alexandre Mebazaa3,4,5
1Department of Cardiovascular Sciences KU Leuven, Campus Gasthuisberg O&N1, Leuven, Belgium.
European Journal of Heart Failure
|April 7, 2018
Summary
No abstract available in PubMed .
Related Concept Videos
Anatomy of the Heart
120.6K
The human heart is made up of three layers of tissue that are surrounded by the pericardium, a membrane that protects and confines the heart. The outermost layer, closest to the pericardium, is the epicardium. The pericardial cavity separates the pericardium from the epicardium. Beneath the epicardium is the myocardium, the middle layer, and the endocardium, the innermost layer. There are four chambers of the heart: the right atrium, the right ventricle, the left atrium, and the left ventricle.
120.6K
Cardiac Catheterization III: Left Heart Catheterization
764
Left heart catheterization is an invasive diagnostic procedure used to evaluate the function and structure of the left side of the heart. It is generally performed to diagnose and treat cardiovascular conditions such as valve abnormalities, coronary artery disease, and congenital heart defects.Diagnostic and therapeutic purposesLeft heart catheterization serves various diagnostic and therapeutic purposes, including:Assessing coronary artery bypass grafts.Evaluating coronary artery disease in...
764
ATP Driven Pumps III: V-type Pumps
4.9K
V-type pumps are ATP-driven pumps found in the vacuolar membranes of plants, yeast, endosomal and lysosomal membranes of animal cells, plasma membranes of a few specialized eukaryotic cells, and some prokaryotes. They are also known as the V1Vo-ATPase, that couple ATP hydrolysis to transport protons against a concentration gradient.
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
4.9K
ATP Driven Pumps II: P-type Pumps
6.5K
The P-type pumps are a large family of integral membrane transporter ATPases. They are divided into five major types based on substrate specificity, from I to V.
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
6.5K
Pumped Concrete
401
Concrete in large quantities can be pumped across long distances for placing in inaccessible sites. This system comprises a hopper that receives concrete from a mixer, a pump to propel the concrete, and pipelines that facilitate its delivery.
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
401
Refrigerators and Heat Pumps
3.1K
Refrigerators or heat pumps are heat engines operating in a reverse direction. For a refrigerator, the focus is on removing heat from a specific area, whereas, for a heat pump, the focus is on dumping heat into one particular area. A refrigerator (or heat pump) absorbs heat Qc from the cold reservoir at Kelvin temperature Tc and discards heat Qh to the hot reservoir at Kelvin temperature Th, while work W is done on the engine’s working substance.
A household refrigerator removes heat from...
A household refrigerator removes heat from...
3.1K

