Related Experiment Video
Updated: Feb 12, 2026

Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Hyperelastic Mechanical Properties of Ex Vivo Normal and Intrauterine Growth Restricted Placenta
Shier Nee Saw1, Jess Yi Ru Low1, May Han Huang Ong1
1Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, #02-04, Singapore, 117575, Singapore.
Intrauterine Growth Restriction (IUGR) is a serious and prevalent pregnancy complication that is due to placental insufficiency and IUGR babies suffer significantly higher risks of mortality and morbidity. Current detection rate for IUGR is generally poor and thus an alternative diagnostic tool is needed to improve the IUGR detection. Elastography, a non-invasive method that measures the tissue stiffness, has been proposed as one such technique. However, to date, we have limited information on the mechanical properties of IUGR placenta. In this study, we investigated the mechanical properties of normal and IUGR placentae and prescribed a suitable hyperelastic model to describe their mechanical behaviors. A total of 46 normal and 43 IUGR placenta samples were investigated. Results showed that placenta samples were isotropic, but had a high spatial variability of stiffness. The samples also had significant viscoelasticity. IUGR placenta was observed to be slightly stiffer than normal placenta but the difference was significant only at compression rate of 0.25 Hz and with 20% compression depth. Three simple hyperelastic models-Yeoh, Ogden and Fung models, were found to be able to fit the experimentally measured mechanical behaviors, and Fung model performed slightly better. These results may be useful for optimizing placenta elastography for the detection of IUGR.
Intrauterine Growth Restriction (IUGR) is a serious and prevalent pregnancy complication that is due to placental insufficiency and IUGR babies suffer significantly higher risks of mortality and morbidity. Current detection rate for IUGR is generally poor and thus an alternative diagnostic tool is needed to improve the IUGR detection. Elastography, a non-invasive method that measures the tissue stiffness, has been proposed as one such technique. However, to date, we have limited information on the mechanical properties of IUGR placenta. In this study, we investigated the mechanical properties of normal and IUGR placentae and prescribed a suitable hyperelastic model to describe their mechanical behaviors. A total of 46 normal and 43 IUGR placenta samples were investigated. Results showed that placenta samples were isotropic, but had a high spatial variability of stiffness. The samples also had significant viscoelasticity. IUGR placenta was observed to be slightly stiffer than normal placenta but the difference was significant only at compression rate of 0.25 Hz and with 20% compression depth. Three simple hyperelastic models-Yeoh, Ogden and Fung models, were found to be able to fit the experimentally measured mechanical behaviors, and Fung model performed slightly better. These results may be useful for optimizing placenta elastography for the detection of IUGR.
Related Concept Videos
Radical Chain-Growth Polymerization: Mechanism
Anionic Chain-Growth Polymerization: Mechanism
Cationic Chain-Growth Polymerization: Mechanism
Restriction Enzymes
The host bacteria protect their own genomic DNA from these enzymes by methylating these sites. Some...
Variation: Normal Distribution, Range, and Standard Deviation
Normal Distribution

