Related Experiment Video
Updated: Feb 12, 2026

Study of Protein Dynamics via Neutron Spin Echo Spectroscopy
Published on: April 13, 2022
Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical
Robert J Harris1,2,3, Jingwen Yao1,2,4, Ararat Chakhoyan1,2
1UCLA Brain Tumor Imaging Laboratory, Center for Computer Vision and Imaging Biomarkers, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California.
Purpose:
To introduce a new pH-sensitive and oxygen-sensitive MRI technique using amine proton CEST echo spin-and-gradient echo (SAGE) EPI (CEST-SAGE-EPI).
Methods:
pH-weighting was obtained using CEST estimations of magnetization transfer ratio asymmetry (MTRasym ) at 3 ppm, and oxygen-weighting was obtained using R2' measurements. Glutamine concentration, pH, and relaxation rates were varied in phantoms to validate simulations and estimate relaxation rates. The values of MTRasym and R2' in normal-appearing white matter, T2 hyperintensity, contrast enhancement, and macroscopic necrosis were measured in 47 gliomas.
Results:
Simulation and phantom results confirmed an increase in MTRasym with decreasing pH. The CEST-SAGE-EPI estimates of R2 , R2*, and R2' varied linearly with gadolinium diethylenetriamine penta-acetic acid concentration (R2 = 6.2 mM-1 ·sec-1 and R2* = 6.9 mM-1 ·sec-1 ). The CEST-SAGE-EPI and Carr-Purcell-Meiboom-Gill estimates of R2 (R2 = 0.9943) and multi-echo gradient-echo estimates of R2* (R2 = 0.9727) were highly correlated. T2 lesions had lower R2' and higher MTRasym compared with normal-appearing white matter, suggesting lower hypoxia and high acidity, whereas contrast-enhancement tumor regions had elevated R2' and MTRasym , indicating high hypoxia and acidity.
Conclusion:
The CEST-SAGE-EPI technique provides simultaneous pH-sensitive and oxygen-sensitive image contrasts for evaluation of the brain tumor microenvironment. Advantages include fast whole-brain acquisition, in-line B0 correction, and simultaneous estimation of CEST effects, R2 , R2*, and R2' at 3 T.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Gas Exchange and Transport
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...