Related Experiment Video
Updated: Feb 12, 2026

Controlled Cervical Laceration Injury in Mice
Published on: May 9, 2013
Quantitative evaluation of facet deflection, stiffness, strain and failure load during simulated cervical spine
Ryan D Quarrington1, John J Costi2, Brian J C Freeman3
1School of Mechanical Engineering, The University of Adelaide, South Australia, Australia; Centre for Orthopaedic & Trauma Research, Adelaide Medical School, The University of Adelaide, South Australia, Australia; Adelaide Spinal Research Group, Adelaide Medical School, The University of Adelaide, South Australia, Australia.
Abstract:
Traumatic cervical facet dislocation (CFD) is often associated with devastating spinal cord injury. Facet fractures commonly occur during CFD, yet quantitative measures of facet deflection, strain, stiffness and failure load have not been reported. The aim of this study was to determine the mechanical response of the subaxial cervical facets when loaded in directions thought to be associated with traumatic bilateral CFD - anterior shear and flexion. Thirty-one functional spinal units (6 × C2/3, C3/4, C4/5, and C6/7, 7 × C5/6) were dissected from fourteen human cadaver cervical spines (mean donor age 69 years, range 48-92; eight male). Loading was applied to the inferior facets of the inferior vertebra to simulate the in vivo inter-facet loading experienced during supraphysiologic anterior shear and flexion motion. Specimens were subjected to three cycles of sub-failure loading (10-100 N, 1 mm/s) in each direction, before being failed in a randomly assigned direction (10 mm/s). Facet deflection, surface strains, stiffness, and failure load were measured. Linear mixed-effects models (α = 0.05; random effect of cadaver) accounted for variations in specimen geometry and bone density. Specimen-specific parameters were significantly associated with most outcome measures. Facet stiffness and failure load were significantly greater in the simulated flexion loading direction, and deflection and surface strains were higher in anterior shear at the non-destructive analysis point (47 N applied load). The sub-failure strains and stiffness responses differed between the upper and lower subaxial cervical regions. Failure occurred through the facet tip during anterior shear loading, while failure through the pedicles was most common in flexion.
More Related Videos
Related Concept Videos
Normal Strain under Axial Loading
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Maximum Deflection
The maximum deflection occurs at a specific point, known as point O, where the tangent to the deflection curve is horizontal. To find point O, the slope of the tangent at any...
Heart Failure IV: Classification and Diagnostic Evaluation
Thermal Strain
Shearing Strain