Role of the impulse oscillometry in the evaluation of tracheal stenosis
R Linhas1, F Lima1, D Coutinho2
1Department of Pulmonology, Centro Hospitalar Vila Nova de Gaia/Espinho, EPE, Portugal.
Introduction And Objectives:
Tracheal stenosis is a rare and challenging disease. Bronchoscopy is the gold standard for diagnosis and assessment but brings inherent risks. Spirometry is commonly used to access obstructions but is not always feasible due to patient related factors. We therefore considered impulse oscillometry (IOS) as a non-invasive method to quantify airway obstruction and its potential use for diagnosis and follow-up of tracheal stenosis.
Materials And Methods:
Patients with confirmed tracheal stenosis were recruited between January 1st, 2015 and December 31st, 2016. Before bronchoscopy, all subjects underwent IOS and spirometry; for patients submitted to interventional bronchoscopy the same techniques were also performed after the procedure. We assessed the correlation between IOS measurements and airway narrowing as well as between IOS and spirometry values.
Results:
Twenty-one patients were included. Tracheal narrowing was inversely correlated with X5% (r -0.442, p 0.045) and positively correlated with FEV1/PEF (r 0.467, p 0.033). The stenosis length was inversely correlated with PEF and PEF% (r -0.729, p=0.001 and r -0.707, p=0.002, respectively). There was a strong correlation between spirometric and IOS values. We did not find any significant differences between pre- and post-intervention IOS values for patients assessed after interventional bronchoscopy.
Conclusions:
Our study showed a weak correlation between X5% and tracheal narrowing making it unclear whether IOS can be used for physiological assessment of patients with tracheal stenosis. Stenosis length correlated with PEF making it a potential predictor of successful surgical approach. The correlation between IOS and spirometric values makes IOS a potential alternative in patients with suspected tracheal stenosis who are not able to perform spirometry. Larger scale studies should clarify the role of IOS in this pathology.
Related Concept Videos
Impulse
Additionally, it can be shown that the...
Impulse Response
Kirchhoff's law forms an input signal equation, with the capacitor's current and voltage providing the output. Substituting the current and dividing by RC yields a differential equation. The output for an impulse input is the impulse...
Role of Communication in the Nursing Process III: Evaluation and Documentation
Principle of Impulse and Moment
Impulse-Momentum Theorem
By writing Newton's second law of motion in terms of the momentum of an object and the external force acting on it, and simultaneously using the definition of the impulse vector, it can be shown that the total impulse on an object is equal to its...
Mitral Stenosis I: Introduction