Dosimetric and Radiobiological Evaluation of Patient Setup Accuracy in Head-and-neck Radiotherapy Using Daily Computed Tomography-on-rails-based Corrections
Related Experiment Video
Updated: Feb 12, 2026

Porcine As a Training Module for Head and Neck Microvascular Reconstruction
Published on: September 29, 2018
Ines-Ana Jurkovic1, Esengul Kocak-Uzel2, Abdallah Sherif Radwan Mohamed3
1Department of Radiation Oncology, University of Texas Health Sciences Center at San Antonio, San Antonio, TX, USA.
Introduction:
This study evaluates treatment plans aiming at determining the expected impact of daily patient setup corrections on the delivered dose distribution and plan parameters in head-and-neck radiotherapy.
Materials And Methods:
In this study, 10 head-and-neck cancer patients are evaluated. For the evaluation of daily changes of the patient internal anatomy, image-guided radiation therapy based on computed tomography (CT)-on-rails was used. The daily-acquired CT-on-rails images were deformedly registered to the CT scan that was used during treatment planning. Two approaches were used during data analysis ("cascade" and "one-to-all"). The dosimetric and radiobiological differences of the dose distributions with and without patient setup correction were calculated. The evaluation is performed using dose-volume histograms; the biologically effective uniform dose () and the complication-free tumor control probability (P+) were also calculated. The dose-response curves of each target and organ at risk (OAR), as well as the corresponding P+ curves, were calculated.
Results:
The average difference for the "one-to-all" case is 0.6 ± 1.8 Gy and for the "cascade" case is 0.5 ± 1.8 Gy. The value of P+ was lowest for the cascade case (in 80% of the patients).
Discussion:
Overall, the lowest PI is observed in the one-to-all cases. Dosimetrically, CT-on-rails data are not worse or better than the planned data.
Conclusions:
The differences between the evaluated "one-to-all" and "cascade" dose distributions were small. Although the differences of those doses against the "planned" dose distributions were small for the majority of the patients, they were large for given patients at risk and OAR.
More Related Videos
08:25Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision