Motorized Micro-Forceps with Active Motion Guidance based on Common-Path SSOCT for Epiretinal Membranectomy
Gyeong Woo Cheon1, Berk Gonenc2, Russell H Taylor3
1Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA.
Abstract:
In this study, we built and tested a handheld motion-guided micro-forceps system using common-path swept source optical coherence tomography (CP-SSOCT) for highly accurate depth controlled epiretinal membranectomy. A touch sensor and two motors were used in the forceps design to minimize the inherent motion artifact while squeezing the tool handle to actuate the tool and grasp, and to independently control the depth of the tool-tip. A smart motion monitoring and a guiding algorithm were devised to provide precise and intuitive freehand control. We compared the involuntary tool-tip motion occurring while grasping with a standard manual micro-forceps and our touch sensor activated micro-forceps. The results showed that our touch-sensor-based and motor-actuated tool can significantly attenuate the motion artifact during grasping (119.81 μm with our device versus 330.73 μm with the standard micro-forceps). By activating the CP-SSOCT based depth locking feature, the erroneous tool-tip motion can be further reduced down to 5.11μm. We evaluated the performance of our device in comparison to the standard instrument in terms of the elapsed time, the number of grasping attempts, and the maximum depth of damage created on the substrate surface while trying to pick up small pieces of fibers (Ø 125 μm) from a soft polymer surface. The results indicate that all metrics were significantly improved when using our device; of note, the average elapsed time, the number of grasping attempts, and the maximum depth of damage were reduced by 25%, 31%, and 75%, respectively.
Related Concept Videos
Mean free path and Mean free time
Common Ion Effect
Path Between Thermodynamics States
Enteric Nervous System: Regulation of GI Motor Activity
During periods of fasting, the ENS initiates the migrating myoelectric complex, a...
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion