Electrochemiluminescence Assays for Human Islet Autoantibodies
Published on: March 23, 2018
Electrochemiluminescence Assays for Human Islet Autoantibodies
Yong Gu1, Zhiyuan Zhao2, Dongmei Miao2
1Barbara Davis Center for Childhood Diabetes, University of Colorado Denver; Department of Endocrinology, First Affiliated Hospital of Nanjing Medical University.
Abstract:
Pinpointing islet autoantibodies associated with type 1 diabetes (T1D) leads the way to project and deter this disease in the general population. A novel ECL assay is a nonradioactive fluid phase assay for islet autoantibodies with higher sensitivity and specificity than the current 'gold' standard radio-binding assay (RBA). ECL assays can more precisely define the onset of presymptomatic T1D by distinguishing the high-risk, high-affinity autoantibodies from the low-risk, low-affinity autoantibodies generated in RBAs, and conventional enzyme-linked immunosorbent assays (ELISA). The antigen protein used in this ECL assay is labeled with Sulfo-tag and Biotin, respectively. Each ECL autoantibody assay that uses a particular antigen protein needs an optimization step before it can be used for laboratory application. This step is especially vital in determining the requirements for serum acid treatments, concentrations, and ratios of the two different antigens labeled with Sulfo-tag and Biotin. To perform the assay, serum samples are mixed with Sulfo-tag-conjugated and biotinylated capture antigen protein in phosphate buffered solution (PBS), containing 5% Bovine Serum Albumin (BSA). Afterwards, the samples are incubated overnight at 4 °C. The same day, a streptavidin-coated plate is prepared with blocker buffer and incubated overnight at 4 °C. On the second day, wash the streptavidin plate and transfer the serum-antigen mixture onto the plate. Place the plate on the plate shaker, set it at low speed, and incubate at room temperature for 1 h. Subsequently, the plate is washed again, and reader buffer is added. The plate is then counted on the plate reader machine. The results are conveyed through an index, which is generated from internal standard positive and negative control serum samples.
Related Concept Videos
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are...
Biodiversity and Human Values
Human Genetics
The complex relationship between genetics and psychology is observable through common biological components such...
Requirements for Human Life
Oxygen
Atmospheric air is only about 20 percent oxygen, but that oxygen is a key component of the chemical reactions that keep the body alive, including the reactions that produce ATP. Brain cells are susceptible to a lack of oxygen because they require a...
Role of Proteins in the Human Body
Maslow's Theory of Basic Human Needs
Physiological needs such as hunger, thirst, sex, physical comfort, and survival are at the bottom of the pyramid. These are the components that are necessary to sustain life. Once the first level of needs has been met, the second level arises.
Safety needs include stability and predictability. Protection and freedom from danger are all a part...