Related Experiment Video
Updated: Feb 12, 2026

Introducing Shear Stress in the Study of Bacterial Adhesion
Published on: September 2, 2011
Clinical Follow-up of a Fissure Sealant Placed Using Different Adhesive Protocols: A 24-month Split-mouth Study
Abstract:
The purpose of this study was to evaluate the retention rates of a fissure sealant placed using different adhesive protocols over 24 months. Twenty-four subjects with no restorations or caries received fissure sealants (Clinpro Sealant, 3M ESPE) placed using different adhesive protocols. A total of 292 sealants were placed as follows by two previously calibrated dentists using a table of random numbers (n=73): group I, acid-etch/without adhesive; group II, with a self-etch adhesive (Adper Easy Bond, 3M ESPE); group III, with an etch-and-rinse adhesive (Adper Single Bond 2, 3M ESPE); group IV, with acid + self-etch adhesive (Adper Easy Bond). Two other calibrated examiners independently evaluated the sealants at baseline and at six-, 12-, 18-, and 24-month recalls. Each sealant was evaluated in terms of caries formation being present or absent and retention using the following criteria: 1 = total retention, 2 = partial loss, and 3 = total loss. Pearson's χ2 test was used to evaluate differences in retention rates among the sealants for each evaluation period. At the end of 24 months, total retention rates were 57.5%, 27.4%, 84.9%, and 76.7% in the acid-etch, self-etch adhesive, etch-and-rinse adhesive, and acid + self-etch adhesive groups, respectively. Although there were no statistically significant differences between the retention rates among the adhesive protocols at 6 months ( p=0.684), significant differences were observed at the 12-, 18-, and 24-month evaluations. At 24 months, the lowest retention rates were observed in the self-etch group ( p<0.05). No caries development was observed in any of the groups. The retention rate of sealants placed using self-etch adhesive was poor compared with the other groups.
More Related Videos
10:30Simultaneously Capturing Real-time Images in Two Emission Channels Using a Dual Camera Emission Splitting System: Applications to Cell Adhesion
Published on: September 4, 2013
07:40Assay of Adhesion Under Shear Stress for the Study of T Lymphocyte-Adhesion Molecule Interactions
Published on: June 29, 2016
Related Concept Videos
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Adhesion
Capillary action is a result of water’s adhesive tendencies. When a narrow...
Aneurysm II: Clinical Manifestations and Diagnostic Studies
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
Holter Monitor: 24-Hour Monitoring
Hypertension III: Clinical Manifestations and Diagnostic Studies