Protected versus Unprotected Carotid Artery Stenting : Meta-Analysis of the Current Literature
Young Dae Cho1, Sung-Eun Kim2, Jeong Wook Lim3
1Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.
Objective:
To compare peri-operative any symptomatic stroke after carotid angioplasty and stenting (CAS), based on the application or absence of a cerebral protection device.
Methods:
A systematic literature review using PubMed, Embase, and the Cochrane Central was done across an online data base from January 1995 to October 2016. Procedures which were performed due to carotid dissection or aneurysm, procedures using covered stents or conducted in an emergency, were excluded. The primary endpoint was perioperative any symptomatic stroke within 30 days after the procedure. A fixed effect model was used in cases of heterogeneity less than 50%.
Results:
In the 25 articles included in this study, the number of stroke events was 326 (2.0%) in protected CAS and 142 (3.4%) in unprotected CAS. The use of cerebral protection device significantly decreased stroke after CAS (odds ratio [OR] 0.633, 95% confidence interval [CI] 0.479-0.837, p=0.001). In the publication bias analysis, Egger's regression test disclosed that the intercept was -0.317 (95% CI -1.015-0.382, p=0.358). Regarding symptomatic patients (four studies, 539 CAS procedures), the number of stroke was six (1.7%) in protected CAS and 11 (5.7%) in unprotected CAS. The protective effect against stroke events by cerebral protection device did not have a statistical significance (OR 0.455, 95% CI 0.151-1.366, p=0.160).
Conclusion:
The use of protection device significantly decreased stroke after CAS. However, its efficacy was not demonstrated in symptomatic patients. Routine use of protection device during CAS should be critically assessed before mandatory use.
Related Concept Videos
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Directing Effect of Substituents: meta-Directing Groups
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protecting Self-Esteem
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...