Use of the MIRUS™ system for general anaesthesia during surgery: a comparison of isoflurane, sevoflurane and
Martin Bellgardt1, Dominik Drees2, Vladimir Vinnikov2
1Department of Anaesthesiology and Intensive Care Medicine, St. Josef Hospital, Ruhr-University Bochum, Gudrunstraße 56, 44791, Bochum, Germany. m.bellgardt@klinikum-bochum.de.
Abstract:
The MIRUS™ system enables automated end-expired control of volatile anaesthetics. The device is positioned between the Y-piece of the breathing system and the patient's airway. The system has been tested in vitro and to provide sedation in the ICU with end-expired concentrations up to 0.5 MAC. We describe its performance in a clinical setting with concentrations up to 1.0 MAC. In 63 ASA II-III patients undergoing elective hip or knee replacement surgery, the MIRUS™ was set to keep the end-expired desflurane, sevoflurane, or isoflurane concentration at 1 MAC while ventilating the patient with the PB-840 ICU ventilator. After 1 h, the ventilation mode was switched from controlled to support mode. Time to 0.5 and 1 MAC, agent usage, and emergence times, work of breathing, and feasibility were assessed. In 60 out of 63 patients 1.0 MAC could be reached and remained constant during surgery. Gas consumption was as follows: desflurane (41.7 ± 7.9 ml h-1), sevoflurane (24.3 ± 4.8 ml h-1) and isoflurane (11.2 ± 3.3 ml h-1). Extubation was faster after desflurane use (min:sec): desflurane 5:27 ± 1:59; sevoflurane 6:19 ± 2:56; and isoflurane 9:31 ± 6:04. The support mode was well tolerated. The MIRUS™ system reliable delivers 1.0 MAC of the modern inhaled agents, both during mechanical ventilation and spontaneous (assisted) breathing. Agent usage is highest with desflurane (highest MAC) but results in the fastest emergence. Trial registry number: Clinical Trials Registry, ref.: NCT0234509.
More Related Videos
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits
Molecular Comparison of Gases, Liquids, and Solids