Related Experiment Video
Updated: Feb 12, 2026

Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight MALDI-TOF Mass Spectrometry
Published on: June 10, 2018
Insight into Identification of Acinetobacter Species by Matrix-Assisted Laser Desorption/Ionization Time of Flight
Xiuyuan Li1, Yanyan Tang1, Xinxin Lu2
1Department of Laboratory Medicine, Beijing Tongren Hospital, Capital Medical University, Legation Street 1#, Beijing, Dongcheng District, 100730, China.
Abstract:
Currently, the capability of identification for Acinetobacter species using MALDI-TOF MS still remains unclear in clinical laboratories due to certain elusory phenomena. Thus, we conducted this research to evaluate this technique and reveal the causes of misidentification. Briefly, a total of 788 Acinetobacter strains were collected and confirmed at the species level by 16S rDNA and rpoB sequencing, and subsequently compared to the identification by MALDI-TOF MS using direct smear and bacterial extraction pretreatments. Cluster analysis was performed based on the mass spectra and 16S rDNA to reflect the diversity among different species. Eventually, 19 Acinetobacter species were confirmed, including 6 species unavailable in Biotyper 3.0 database. Another novel species was observed, temporarily named A. corallinus. The accuracy of identification for Acinetobacter species using MALDI-TOF MS was 97.08% (765/788), regardless of which pretreatment was applied. The misidentification only occurred on 3 A. parvus strains and 20 strains of species unavailable in the database. The proportions of strains with identification score ≥ 2.000 using direct smear and bacterial extraction pretreatments were 86.04% (678/788) and 95.43% (752/788), χ2 = 41.336, P < 0.001. The species similar in 16 rDNA were discriminative from the mass spectra, such as A. baumannii & A. junii, A. pittii & A. calcoaceticus, and A. nosocomialis & A. seifertii. Therefore, using MALDI-TOF MS to identify Acinetobacter strains isolated from clinical samples was deemed reliable. Misidentification occurred occasionally due to the insufficiency of the database rather than sample extraction failure. We suggest gene sequencing should be performed when the identification score is under 2.000 even when using bacterial extraction pretreatment. Graphical Abstract ᅟ.
More Related Videos
07:49Matrix-assisted Laser Desorption/Ionization Time of Flight MALDI-TOF Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
12:19Uracil-DNA Glycosylase Assay by Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry Analysis
Published on: April 22, 2022
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
MALDI-TOF Mass Spectrometry
Chemical Ionization (CI) Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Ionization Energy