Related Experiment Video
Updated: Feb 12, 2026

Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
Double Reading in Breast Cancer Screening: Cohort Evaluation in the CO-OPS Trial
Sian Taylor-Phillips1, David Jenkinson1, Chris Stinton1
1From the Warwick Medical School, University of Warwick, Gibbett Hill Rd, Coventry CV4 7AL, England (S.T., D.J., C.S., J.D., A.C.); and Cambridge Breast Unit, Cambridge University Hospitals National Health Service Foundation Trust, and National Institute for Health Research Cambridge Biomedical Research Centre, Cambridge, England (M.G.W.).
Abstract:
Purpose To investigate the effect of double readings by a second radiologist on recall rates, cancer detection, and characteristics of cancers detected in the National Health Service Breast Screening Program in England. Materials and Methods In this retrospective analysis, 805 206 women were evaluated through screening and diagnostic test results by extracting 1 year of routine data from 33 English breast screening centers. Centers used double reading of digital mammograms, with arbitration if there were discrepant interpretations. Information on reader decisions, with results of follow-up tests, were used to explore the effect of the second reader. The statistical tests used were the test for equality of proportions, the χ2 test for independence, and the t test. Results The first reader recalled 4.76% of women (38 295 of 805 206 women; 95% confidence interval [CI]: 4.71%, 4.80%). Two readers recalled 6.19% of women in total (49 857 of 805 206 women; 95% CI: 6.14%, 6.24%), but arbitration of discordant readings reduced the recall rate to 4.08% (32 863 of 805 206 women; 95% CI: 4.04%, 4.12%; P < .001). A total of 7055 cancers were detected, of which 627 (8.89%; 95% CI: 8.22%, 9.55%; P < .001) were detected by the second reader only. These additional cancers were more likely to be ductal carcinoma in situ (30.5% [183 of 600] vs 22.0% [1344 of 6114]; P < .001), and additional invasive cancers were smaller (mean size, 14.2 vs 16.7 mm; P < .001), had fewer involved nodes, and were likely to be lower grade. Conclusion Double reading with arbitration reduces recall and increases cancer detection compared with single reading. Cancers detected only by the second reader were smaller, of lower grade, and had less nodal involvement. © RSNA, 2018.
Related Concept Videos
Cascaded Op Amps
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
Second-order Op Amp Circuits
The analysis of such circuits follows a systematic approach, similar to the second-order RLC circuits. In practical scenarios, bulky inductors are rarely employed due to their size and weight. This means...
Uncertainty in Measurement: Reading Instruments
Fixing Double-strand Breaks
Trial and Error and Algorithm
Clinical Trials: Overview

