Related Experiment Video
Updated: Feb 12, 2026

A Human Ex Vivo Atherosclerotic Plaque Model to Study Lesion Biology
Published on: May 6, 2014
Biological Lenticule Implantation for Correction of Hyperopia: An Ex Vivo Study in Human Corneas
Purpose:
To evaluate changes in corneal tomography after stromal lenticule implantation ex vivo, with respect to the dependency of the lenticule thickness and implantation depth on the corneal curvature and the postoperative biomechanical strength at increased chamber pressure.
Methods:
Twenty-eight human donor corneas underwent pocket implantation of refractive stromal lenticules. Four groups were created by the combination of two implantation depths (110 and 160 µm) and two lenticule thicknesses (95 µm = 4.00 diopters [D], 150 µm = 8.00 D). Sagittal keratometry and total corneal refractive power (TCRP4mm,apex,zone) were obtained for the front and back curvature with Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) at chamber pressures of 15 and 40 mm Hg.
Results:
The anterior curvature steepening was comparable between the 4.00 D and 8.00 D groups (P > .141), but more pronounced with 110 µm implantation depth (P < .038). The posterior curvature flattened significantly more after implantation of 8.00 D than 4.00 D lenticules (P < .002), but was similar at 110 and 160 µm implantation depths (P > .071). Average ΔTCRP for the 4.00 D and 8.00 D groups was 3.10 ± 0.60 and 5.30 ± 1.66 diopters (D) at 110-µm depth, respectively (P = .003), but 1.99 ± 0.79 and 3.36 ± 1.45 D at 160-µm depth, respectively (P = .066). The relative correction achieved was 66% to 78% at 110-µm depth and 42% to 50% at 160-µm depth, but similar when using 4.00 D and 8.00 D lenticules. Increased chamber pressure caused significant anterior and posterior curvature steepening after implantation in all four groups (P < .001), but not before implantation (P > .632).
Conclusions:
The power of the implanted lenticule must be higher than the intended correction, and customized to the chosen implantation depth. Biomechanical strength seems to decrease after lenticule implantation. [J Refract Surg. 2018;34(4):245-252.].
Related Concept Videos
Distance Corrections
Role of Water in Human Biology
Water's Solvent Properties
Since water is a polar molecule with slightly positive and slightly negative charges, ions and polar molecules can readily dissolve in it. Therefore, it is referred to as a solvent, a...
What is Conservation Biology?
Power Factor Correction
Biological Effects of Radiation
NMR Spectrometers: Resolution and Error Correction

