Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Personal Protective Equipment01:20

Personal Protective Equipment

2.4K
Personal protective equipment (PPE) is unique clothing or equipment worn by an employee to minimize or prevent exposure to infectious agents. PPE creates a barrier between the employee and the infectious materials. PPE must be readily available in the patient care area. PPE includes gloves, gowns and aprons, masks and respirators, goggles, face shields, shoes, and headcovers:
2.4K
The Sense of Self: Reflected Self-Appraisal and Social Comparison02:57

The Sense of Self: Reflected Self-Appraisal and Social Comparison

56.1K
According to Charles Cooley, we base our image on what we think other people see (Cooley 1902). We imagine how we must appear to others, then react to this speculation. We don certain clothes, prepare our hair in a particular manner, wear makeup, use cologne, and the like—all with the notion that our presentation of ourselves is going to affect how others perceive us. We expect a certain reaction, and, if lucky, we get the one we desire and feel good about it. But more than that, Cooley...
56.1K
Uniform Distribution01:19

Uniform Distribution

6.1K
The uniform distribution is a continuous probability distribution of events with an equal probability of occurrence. This distribution is rectangular.
Two essential properties of this distribution are
6.1K
Leveling Equipment01:18

Leveling Equipment

443
As leveling involves measuring vertical distances relative to a horizontal line of sight, it requires a graduated rod, called a level rod, for vertical measurements and an instrument called a level for a horizontal sight line. A level includes a high-powered telescope with a mechanism for leveling to ensure the line of sight is horizontal when the bubble in the spirit level is centered. Leveling rods, made of wood, metal, or fiberglass, are graduated in feet or meters and commonly used in two-...
443
Pharmacokinetic Models: Comparison and Selection Criterion01:26

Pharmacokinetic Models: Comparison and Selection Criterion

369
Physiological and compartmental models are valuable tools used in studying biological systems. These models rely on differential equations to maintain mass balance within the system, ensuring an accurate representation of the dynamic processes at play.
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
369
Uniform Circular Motion01:14

Uniform Circular Motion

22.4K
Uniform circular motion is a specific type of motion in which an object travels in a circle with a constant speed. For example, any point on a propeller spinning at a constant rate is undergoing uniform circular motion. The second, minute, and hour hands of a watch also undergo uniform circular motion. It is hard to believe that points on these rotating objects are actually accelerating, even though the rotation rate is constant. To understand this, we must analyze the motion in terms of...
22.4K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Introduction to the Special Section on Improving Health Care Access.

The Permanente journal·2026
Same author

The Survival and Success of Teeth With External Cervical Resorption: A Multi-Centre, Retrospective Study.

International endodontic journal·2026
Same author

Description of an independently developed quality assessment tool to meet emergency department credentialing and Emergency Ultrasound Fellowship Accreditation Council guidelines.

The ultrasound journal·2026
Same author

56-Year-Old Man With Dyspnea and Volume Overload.

Journal of the American College of Emergency Physicians open·2026
Same author

Transthoracic echocardiography is superior to AHA guidelines location in identifying the left ventricle for chest compressions.

Resuscitation plus·2026
Same author

Mentorship Strategies and Illustrative Cases at Every Career Stage.

AEM education and training·2026

Related Experiment Video

Updated: Feb 12, 2026

Solution Blow Spinning of Polymeric Nano-Composite Fibers for Personal Protective Equipment
07:08

Solution Blow Spinning of Polymeric Nano-Composite Fibers for Personal Protective Equipment

Published on: March 18, 2021

3.5K

Comparison of Intubation Using Personal Protective Equipment and Standard Uniform in Simulated Cadaveric Models.

Alex Koo1, Ryan Walsh1, Tristan Knutson1

  • 1Department of Emergency Medicine, Madigan Army Medical Center, 9040 Jackson Avenue, Tacoma, WA 98433.

Military Medicine
|April 11, 2018
PubMed
Summary

Personal protection equipment (PPE) did not significantly increase intubation times but reduced success rates and increased perceived difficulty during emergency medicine procedures in cadaver models.

More Related Videos

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
04:30

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine

Published on: August 25, 2022

4.1K
Vacuum-Sealed Hot Water Bath Immersion for the Preparation of Anatomical and Surgical Cadaveric Bone Models
04:36

Vacuum-Sealed Hot Water Bath Immersion for the Preparation of Anatomical and Surgical Cadaveric Bone Models

Published on: December 2, 2022

1.7K

Related Experiment Videos

Last Updated: Feb 12, 2026

Solution Blow Spinning of Polymeric Nano-Composite Fibers for Personal Protective Equipment
07:08

Solution Blow Spinning of Polymeric Nano-Composite Fibers for Personal Protective Equipment

Published on: March 18, 2021

3.5K
Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
04:30

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine

Published on: August 25, 2022

4.1K
Vacuum-Sealed Hot Water Bath Immersion for the Preparation of Anatomical and Surgical Cadaveric Bone Models
04:36

Vacuum-Sealed Hot Water Bath Immersion for the Preparation of Anatomical and Surgical Cadaveric Bone Models

Published on: December 2, 2022

1.7K

Area of Science:

  • Emergency Medicine
  • Medical Device Effectiveness

Background:

  • Personal protection equipment (PPE) is crucial for patient safety but may impact clinical procedures.
  • Understanding the effects of PPE on airway management is essential for optimizing patient care.

Purpose of the Study:

  • To evaluate the impact of basic personal protection equipment (PPE) on endotracheal intubation.
  • To compare intubation times, success rates, and perceived difficulty with and without PPE in a cadaver model.

Main Methods:

  • A prospective crossover study design was employed with emergency medicine residents.
  • Intubation performance was assessed in two conditions: standard uniform and with full PPE.
  • Key metrics included intubation time, success rate, and perceived difficulty.

Main Results:

  • Mean intubation times were similar between standard uniform (18.85s) and PPE (19.29s) groups.
  • Intubation success rates were significantly higher in the standard uniform group (83%) compared to the PPE group (72%).
  • Perceived difficulty was significantly higher when using PPE (3.38) versus standard uniform.

Conclusions:

  • While PPE does not significantly prolong intubation time, it is associated with lower success rates.
  • Increased perceived difficulty with PPE during intubation warrants further investigation.