Related Experiment Video
Updated: Feb 12, 2026

Sigma's Non-specific Protease Activity Assay - Casein as a Substrate
Published on: September 17, 2008
Ten-Year Results of the Press Fit Condylar Sigma Cobalt-Chrome Total Knee Replacement
Oisin Keenan1, Ivan Brenkel1, Phil Walmsley1
1Department of Orthopaedics and Trauma, Victoria Hospital, Kirkcaldy, Fife, United Kingdom.
Abstract:
Total knee arthroplasty (TKA) is reliant on safe and effective implants. The Press Fit Condylar Sigma Cobalt-Chrome (PFCSCC) was introduced in 2006, but no reports have examined long-term failure rates and patient-reported outcome measures (PROMs). The primary aim of this study was to assess survival outcomes of the PFCSCC at 10 years after implantation. Prospective data collection was performed on all patients undergoing primary TKA in one orthopaedic department using this prosthesis exclusively from February 1, 2006, to January 31, 2007. Follow-up was at 10 years. Survival analysis was performed using two primary outcome measures: (1) all-cause joint revision and (2) aseptic revision. Secondary outcomes measures included the American Knee Society Score (AKSS) and Oxford Knee Score (OKS). In total, 249 knees of 233 patients underwent primary TKA. Mean patient age was 66.7 years (range 34-80), and mean body mass index (BMI) was 30 kg/m2 (20.7-40.1). Reviewing all causes of revisions, 14 joints (5.6%) of 14 patients required reoperation. Of these, nine were for deep infection, including six in the first year. Four (1.6%) underwent aseptic revision. Mean AKSS changed from 47.6 to 90.4 (n = 140; p < 0.001) at 10 years, and mean OKS changed from 38.3 to 23.2 (n = 149; p < 0.001). Prospective analysis of consecutive TKA cases using this design of prosthesis demonstrated high survival rates of 94.4% (all-cause revision) and 98.4% (aseptic revision) at 10 years. Postoperative gains in PROMs were sustained at 10 years. These real-world data represent a substantial extension to previous reports for the PFCSCC and suggest that it is not prone to late mechanical failure.
Related Concept Videos
Induced-fit Model
Enzymes exhibit substrate specificity, meaning that they can only bind to certain substrates. This is mainly determined by the shape and chemical...
Inclusive Fitness
Goodness-of-Fit Test
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Continuous Renal Replacement Therapy
Expected Frequencies in Goodness-of-Fit Tests