Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
Pressure monitoring predicts pulmonary vein occlusion in cryoballoon ablation
Akihiro Sunaga1, Masaharu Masuda2, Mitsutoshi Asai1
1Kansai Rosai Hospital Cardiovascular Center, 3-1-69, Inabaso, Amagasakishi, Hyogo, 660-8511, Japan.
Purpose:
Pulmonary venography is routinely used to confirm pulmonary vein (PV) occlusion during cryoballoon ablation. However, this technique is significantly limited by the risks associated with contrast media, such as renal injury and contrast allergy. We hypothesized that PV occlusion can be predicted by elevation of the balloon catheter tip pressure, avoiding the need for contrast media.
Methods:
Forty-eight consecutive patients with paroxysmal atrial fibrillation who underwent PV isolation with the cryoballoon technique were enrolled. The balloon catheter tip pressure was measured in each PV before and after balloon inflation.
Results:
We analyzed 200 applications of cryoballoon ablation in 185 PVs (excluding 3 common PVs and 1 extremely small right inferior PV) of 48 patients (age, 70 ± 11 years; male, n = 28; mean left atrial diameter, 38 ± 6 mm). Compared with patients with unsuccessful occlusion, patients with successful occlusion demonstrated a larger change in pressure after balloon inflation (6 ± 8 vs. 2 ± 4 mmHg, P < 0.001), a lower minimum temperature (- 49 ± 6 vs. - 40 ± 8 °C, P < 0.001), and a higher PV isolation rate (97 vs. 64%, P < 0.001). The best cutoff value of a change in pressure for predicting PV occlusion was 4.5 mmHg, with a sensitivity of 67%, specificity of 83%, and predictive accuracy of 72%.
Conclusion:
Pressure monitoring is helpful to confirm PV occlusion during cryoballoon ablation.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
05:35Imaging Ca2+ Signals in Small Pulmonary Veins at Physiological Intraluminal Pressures
Published on: March 21, 2025
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Predicting Molecular Geometry
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
Constant Pressure Calorimetry
Vapor Pressure