Related Experiment Video
Updated: Feb 12, 2026

Introduction to the Ultrasound Targeted Microbubble Destruction Technique
Published on: June 12, 2011
Controllable Formation of Monodisperse Polymer Microbubbles as Ultrasound Contrast Agents
Ruyuan Song, Chuan Peng1, Xiaonan Xu
1State Key Laboratory of Oncology in South China, Collaborative Innovation Center of Cancer Medicine, Department of Ultrasound , Sun Yat-sen University Cancer Center , 510060 Guangzhou , China.
Abstract:
Microbubbles have been widely used as ultrasound contrast agents in clinical diagnosis and hold great potential for ultrasound-mediated therapy. However, polydispersed population and short half-life time (<10 min) of the microbubbles still limit their applications in imaging and therapy. To tackle these problems, we develop a microfluidic flow-focusing approach to produce monodisperse microbubbles stabilized by Poly(lactic-co-glycolic acid) (PLGA) as the polymer shell. The size of PLGA microbubbles can be tightly controlled from ∼600 nm to ∼7 μm with a coefficient of variation less than 4% in size distribution for ensuring highly homogeneous echogenic behavior of PLGA polymer microbubbles in ultrasound fields. Both in vitro and in vivo experiments showed that the monodisperse PLGA microbubbles had excellent echogenicity and elongated sonographic duration time (>3 times) for ultrasound imaging in comparison with the commercial lipid microbubbles.
More Related Videos
08:20Capillary-based Centrifugal Microfluidic Device for Size-controllable Formation of Monodisperse Microdroplets
Published on: February 22, 2016
09:53The Preparation of Chicken Ex Ovo Embryos and Chorioallantoic Membrane Vessels as In Vivo Model for Contrast-Enhanced Ultrasound Imaging and Microbubble-Mediated Drug Delivery Studies
Published on: February 9, 2021
Related Concept Videos
Chemical Agents for Microbial Control
Polymers
Polymers
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):