Related Experiment Video
Updated: Feb 12, 2026

Development of a Novel Task-oriented Rehabilitation Program using a Bimanual Exoskeleton Robotic Hand
Published on: May 20, 2020
Retraining of Human Gait - Are Lightweight Cable-Driven Leg Exoskeleton Designs Effective?
Abstract:
Exoskeletons for gait training commonly use a rigid-linked "skeleton" which makes them heavy and bulky. Cable-driven exoskeletons eliminate the rigid-linked skeleton, providing a lighter and transparent design. Current cable-driven exoskeletons are aimed only at gait assistance by providing short bursts of forces to the leg during walking. It has not yet been shown if these designs are suitable for gait retraining, where rehabilitative forces need to be continuously applied to the leg in response to errors from a desired movement. The goal of this study is to investigate if a cable-driven leg exoskeleton can retrain the gait of human users. Nine healthy subjects were trained by a cable-driven leg exoskeleton to walk in a new gait pattern with 30% increase in step height from their natural gait. After 40 min of training, the gait of the subjects became significantly closer to the target gait than before the training. In three different post-training sessions, the step height of the subjects increased by 22%, 29%, and 31% on an average. In a fourth post-training session, when the subjects were instructed to ignore the training and walk naturally, the step height remained increased by 11%. These results confirm the potential of cable-driven designs in gait training applications.
Related Concept Videos
Cable: Problem Solving
Muscles that Move the Leg
Anterior Compartment
The quadriceps femoris, the most visible muscle of the anterior compartment, is integral for leg extension and thigh flexion. It is formed by merging four distinct muscles — the vastus lateralis, vastus medialis, vastus intermedius, and rectus femoris. The quadriceps tendon, a shared tendon of the four quadriceps muscles, is affixed...
Group Design
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Factorial Design
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field inside...