Testicular necrosis secondary to incarcerated inguinal hernia in male infants. Own observations

Teresa Dudek-Warchoł1, Wojciech Gług2, Aleksandra Kurek2

  • 1Department of Pediatric Surgery and Urology, Medical University of Warsaw, Warsaw, Poland.

Insights

Incarcerated inguinal hernias in infants can cause testicular necrosis, leading to testicular loss. Prompt surgical intervention is crucial for preserving testicular viability.

Area of Science:

  • Pediatric Surgery
  • Urology
  • Neonatal Care

Background:

  • Incarcerated inguinal hernias in infants can lead to testicular ischemia and atrophy.
  • Testicular necrosis is a rare but severe complication of prolonged hernia incarceration.

Purpose of the Study:

  • To highlight the risk of testicular necrosis in infants with incarcerated inguinal hernias.
  • To emphasize the need for rapid diagnosis and surgical intervention.

Main Methods:

  • Case series of 4 male infants with incarcerated inguinal hernias.
  • Intraoperative findings of testicular necrosis.
  • Review of incarceration duration and treatment outcomes.

Main Results:

  • All 4 infants presented with irreducible incarcerated hernias requiring surgery.
  • Intraoperative findings revealed testicular necrosis in all cases.
  • Incarceration time ranged from 4 to 12 hours (mean 6.75 hours).

Conclusions:

  • Incarcerated inguinal hernias in very young male infants necessitate urgent surgical treatment.
  • Ultrasound should assess blood flow to both the hernia and the testis.
  • Intraoperative testicular assessment is vital during hernia repair surgery.

Related Concept Videos

Necrosis01:16

Necrosis

Necrosis is considered as an “accidental” or unexpected form of cell death that ends in cell lysis. The first noticeable mention of “necrosis” was in 1859 when Rudolf Virchow used this term to describe advanced tissue breakdown in his compilation titled “Cell Pathology”.
Morphological Manifestations of Necrosis
Necrotic cells show different types of morphological appearance depending on the type of tissue and infection. In coagulative necrosis, cells become...
6.7K
Secondary Active Transport01:55

Secondary Active Transport

One example of how cells use the energy contained in electrochemical gradients is demonstrated by glucose transport into cells. The ion vital to this process is sodium (Na+), which is typically present in higher concentrations extracellularly than in the cytosol. Such a concentration difference is due, in part, to the action of an enzyme “pump” embedded in the cellular membrane that actively expels Na+ from a cell. Importantly, as this pump contributes to the high concentration of...
138.2K
Infertility in Males01:23

Infertility in Males

Male infertility affects millions of couples worldwide, arising from various factors that impact different stages of the reproductive process. An endocrine imbalance resulting from conditions like hypogonadism, Klinefelter syndrome, or pituitary disorders can disrupt hormone levels and reduce sperm production. Testicular defects, such as tumors, cryptorchidism, atrophic testes, abnormal sperm morphology, and low sperm count or motility, may arise due to genetic factors, structural...
579
Secondary Healthcare System01:11

Secondary Healthcare System

Secondary healthcare is offered by a specialist, generally in hospitals or clinics for patients referred by primary healthcare providers. It occurs when a person has an illness or injury that requires specific medical care. Secondary care is often referred to as acute care. Secondary care can range from uncomplicated care to repair a minor laceration or treat a strep throat infection to more complicated emergent care, such as treating a head injury sustained in an automobile accident. Whatever...
2.1K
Primary and Secondary Growth in Roots and Shoots03:02

Primary and Secondary Growth in Roots and Shoots

Vascular plants, which account for over 90% of the Earth’s vegetation, all undergo primary growth—which lengthens roots and shoots. Many land plants, notably woody plants, also undergo secondary growth—which thickens roots and shoots.
60.7K
Secondary Distribution01:25

Secondary Distribution

Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
583