Bedside ultrasound diagnosis of a malpositioned central venous catheter: A case report
Feier Song1, Daozheng Huang, Ying Chen
1Department of Cardiology, Guangdong Cardiovascular Institue, Guangdong General Hospital, Guangdong Academy of Medical Sciences Department of Critical Care Medicine, Guangdong Geriatric Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences Department of Critical Care Medicine, Yunnan Cancer Hospital Department of Critical Care Medicine, Zhongshan Dongsheng Hospital, Guangzhou, Guangdong Province, China.
Rationale:
Central venous catheter (CVC) placement is commonly performed in intensive care unit. And CVC placement is associated with risks including CVC malposition, pneumothorax. Many of the previously reported cases are about catheter misplacement detected by bedside ultrasound, chest x-ray (CXR) and computed tomography. In this case, malposition was detected by bedside ultrasound incidentally particularly with no clinical manifestation.
Patient Concerns:
An 88-year-old male with severe diabetic peripheral neuropathy secondary to type 2 diabetes mellitus was admitted for further treatment.
Diagnoses:
We cannulated a single-lumen CVC via the right subclavian vein, and the tip ended up in the internal jugular vein on the same side. With bedside ultrasound, we discovered the malposition though it was mistaken by aspiration of venous blood. Later, CXR revealed malposition of the tip once again.
Interventions:
Since the patient was asymptomatic and the catheter was functioning normally, the catheter was used for the following 20 days without complications. Ultimately, we carefully performed the catheter removal.
Outcomes:
After the inserted catheter was removed, we attempted a new CVC through the left internal jugular vein. After the procedure, bedside ultrasound and CXR confirmed the correct position of CVC. Following successful replacement of the central catheter, no further complications were observed.
Lessons:
Bedside ultrasound offers safety and effectiveness during insertion of CVC. It also exhibits promptness and accuracy compared to post-intervention radiological imaging.
More Related Videos
09:57A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
10:09Drug Treatment by Central Venous Catheter in a Mouse Model of Angiotensin II Induced Abdominal Aortic Aneurysm and Monitoring by 3D Ultrasound
Published on: August 4, 2022
Related Concept Videos
Measures of Central Tendency
The Central Dogma
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Venous Thrombosis I: Introduction
Data Reporting and Recording
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...