Related Experiment Video
Updated: Feb 12, 2026

A Reverse Genetic Approach to Test Functional Redundancy During Embryogenesis
Published on: August 11, 2010
Differential coactivation in a redundant signals task with weak and strong go/no-go stimuli
Katsumi Minakata1, Matthias Gondan2
11 DTU Management Engineering, Technical University of Denmark, Kongens Lyngby, Denmark.
Abstract:
When participants respond to stimuli of two sources, response times (RTs) are often faster when both stimuli are presented together relative to the RTs obtained when presented separately (redundant signals effect [RSE]). Race models and coactivation models can explain the RSE. In race models, separate channels process the two stimulus components, and the faster processing time determines the overall RT. In audiovisual experiments, the RSE is often higher than predicted by race models, and coactivation models have been proposed that assume integrated processing of the two stimuli. Where does coactivation occur? We implemented a go/no-go task with randomly intermixed weak and strong auditory, visual, and audiovisual stimuli. In one experimental session, participants had to respond to strong stimuli and withhold their response to weak stimuli. In the other session, these roles were reversed. Interestingly, coactivation was only observed in the experimental session in which participants had to respond to strong stimuli. If weak stimuli served as targets, results were widely consistent with the race model prediction. The pattern of results contradicts the inverse effectiveness law. We present two models that explain the result in terms of absolute and relative thresholds.
More Related Videos
Related Concept Videos
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Titration of a Weak Acid with a Strong Base
Weak Base Solutions
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Weak Acid Solutions

