Related Experiment Video
Updated: Feb 12, 2026

Development of automated imaging and analysis for zebrafish chemical screens.
Published on: June 24, 2010
Pilot Study of an Open-source Image Analysis Software for Automated Screening of Conventional Cervical Smears
Parikshit Sanyal1, Prosenjit Ganguli1, Sanghita Barui1
1Department of Pathology, Command Hospital (EC), Alipore, Kolkata, West Bengal, India.
Introduction:
The Pap stained cervical smear is a screening tool for cervical cancer. Commercial systems are used for automated screening of liquid based cervical smears. However, there is no image analysis software used for conventional cervical smears. The aim of this study was to develop and test the diagnostic accuracy of a software for analysis of conventional smears.
Materials And Methods:
The software was developed using Python programming language and open source libraries. It was standardized with images from Bethesda Interobserver Reproducibility Project. One hundred and thirty images from smears which were reported Negative for Intraepithelial Lesion or Malignancy (NILM), and 45 images where some abnormality has been reported, were collected from the archives of the hospital. The software was then tested on the images.
Results:
The software was able to segregate images based on overall nuclear: cytoplasmic ratio, coefficient of variation (CV) in nuclear size, nuclear membrane irregularity, and clustering. 68.88% of abnormal images were flagged by the software, as well as 19.23% of NILM images. The major difficulties faced were segmentation of overlapping cell clusters and separation of neutrophils.
Conclusion:
The software shows potential as a screening tool for conventional cervical smears; however, further refinement in technique is required.
Related Concept Videos
GIS Software, Hardware, and Sources of GIS Data
Sputum Studies I: Gram Stain, cytology, and Acid-fast smear and culture
Gram Stain
The Gram Stain is an integral part of sputum studies. It involves the staining of sputum, which permits...
Pilot and Numeric Relaying
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Nodal Analysis with Voltage Sources
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
Statistical Software for Data Analysis and Clinical Trials