Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Pathologic confirmation of valve thrombosis detected by four-dimensional computed tomography following valve-in-valve
Ambarish Gopal1, Nathalia Ribeiro1, John J Squiers1
1The Heart Hospital Baylor Plano, 4716 Alliance Blvd, Suite 340, Plano, TX 75093, USA.
Insights
Leaflet thrombosis is a concern after transcatheter aortic valve replacement (TAVR). This study provides the first pathologic confirmation of TAVR leaflet thrombosis identified by four-dimensional computed tomography (4D-CT) in a surgically explanted valve from a surviving patient.
Area of Science:
- Cardiovascular Imaging
- Cardiac Surgery
- Pathology
Background:
- Leaflet thrombosis is a significant complication following transcatheter aortic valve replacement (TAVR).
- Four-dimensional computed tomography (4D-CT) is the primary imaging technique for diagnosing suspected TAVR leaflet thrombosis.
- Pathologic confirmation of 4D-CT findings in surviving patients has been lacking.
Observation:
- This study presents a unique case of a surgically explanted TAVR prosthesis.
- The explanted valve exhibited confirmed thrombus formation.
- The leaflet thrombosis was initially identified using 4D-CT imaging.
Findings:
- Pathologic examination confirmed the presence of thrombus on the TAVR prosthesis leaflets.
- These findings provide direct correlation between 4D-CT imaging and the actual pathologic state of leaflet thrombosis.
- This represents the first instance of pathologic confirmation in a surviving patient.
Implications:
- This study validates the diagnostic accuracy of 4D-CT for detecting TAVR leaflet thrombosis.
- It reinforces the importance of 4D-CT in the clinical management of patients post-TAVR.
- Understanding the pathologic basis of imaging findings can improve patient outcomes and treatment strategies.
Abstract:
A major concern regarding transcatheter aortic valve replacement (TAVR) is leaflet thrombosis. Four-dimensional computed tomography (4D-CT) is the preferred imaging modality to evaluate patients with suspected valve thrombosis. To date, the abnormal findings visualized by 4D-CT suggestive of leaflet thrombosis have lacked pathologic confirmation from a surgically explanted valve in a surviving patient. Herein, we provide pathologic confirmation of thrombus formation following surgical explantation of a thrombosed TAVR prosthesis that was initially identified by 4D-CT.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography