Related Experiment Video
Updated: Feb 12, 2026

Highly Sensitive and Rapid Fluorescence Detection with a Portable FRET Analyzer
Published on: October 1, 2016
Effective Bioactivity Retention of Low-Concentration Antibodies on HFBI-Modified Fluorescence ICTS for Sensitive and
Bo Zhang1, Weichen Gao1, Jiafang Piao1
1School of Life Sciences, Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology, Collaborative Innovation Center of Chemical Science and Engineering (Tianjin) , Tianjin University , Tianjin 300072 , China.
Nowadays, increasing analytical sensitivity is still a big challenge in constructing membrane-based fluorescence immunochromatography test strips (FICTS). However, the bioactivity of antibody (Ab) immobilized on the test line (T line) of porous nitrocellulose membrane (PNM), which directly influences the analytical sensitivity, is less studied. In this work, a novel amphiphilic hydrophobin (HFBI) protein was introduced to modify the T line to effectively retain the Abs' bioactivity. The results indicated that HFBI could self-assemble on the PNM and immobilize the Abs in the "stand-up" orientation. Compared with the conventional FICTS, the HFBI-modified FICTS with only 0.2 mg/mL of monoclonal Abs on T line enable more accurate quantitative detection and better sensitivity (0.06 ng/mL for prostate specific antigen), which is more than 2 orders of magnitude lower than that of the conventional FICTS with the same concentration of monoclonal Abs on T line. Furthermore, the accuracy of this HFBI-modified FICTS was investigated by testing 150 clinical serum samples and the detection results were coincident with those by electrochemiluminescence immunoassay. Our results provide a novel and promising strategy of Ab immobilization on FICTS for near-patient and point-of-care application.
Nowadays, increasing analytical sensitivity is still a big challenge in constructing membrane-based fluorescence immunochromatography test strips (FICTS). However, the bioactivity of antibody (Ab) immobilized on the test line (T line) of porous nitrocellulose membrane (PNM), which directly influences the analytical sensitivity, is less studied. In this work, a novel amphiphilic hydrophobin (HFBI) protein was introduced to modify the T line to effectively retain the Abs' bioactivity. The results indicated that HFBI could self-assemble on the PNM and immobilize the Abs in the "stand-up" orientation. Compared with the conventional FICTS, the HFBI-modified FICTS with only 0.2 mg/mL of monoclonal Abs on T line enable more accurate quantitative detection and better sensitivity (0.06 ng/mL for prostate specific antigen), which is more than 2 orders of magnitude lower than that of the conventional FICTS with the same concentration of monoclonal Abs on T line. Furthermore, the accuracy of this HFBI-modified FICTS was investigated by testing 150 clinical serum samples and the detection results were coincident with those by electrochemiluminescence immunoassay. Our results provide a novel and promising strategy of Ab immobilization on FICTS for near-patient and point-of-care application.
More Related Videos
Related Concept Videos
Radical Reactivity: Concentration Effects
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Biological Effects of Radiation
Concentration Cells
Consider the following voltaic cell:
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Solution Concentration and Dilution

