Related Experiment Video
Updated: Feb 12, 2026

Treating Low Back Pain in Failed Back Surgery Patients with Multicolumn-lead Spinal Cord Stimulation
Published on: June 26, 2018
The Safety and Efficacy of Supraciliary Stenting Following Failed Glaucoma Surgery
Nathan M Kerr1, Jing Wang2, Lucia Perucho2
1Moorfields Eye Hospital, London, United Kingdom; UCL Institute of Ophthalmology, London, United Kingdom.
Purpose:
To evaluate the safety and efficacy of supraciliary stenting following failed glaucoma surgery.
Design:
Interventional case series.
Methods:
Setting: Moorfields Eye Hospital, London, United Kingdom.
Study Population:
Twenty eyes from 20 patients with glaucoma refractory to prior glaucoma surgery.
Intervention:
Ab interno microstent (CyPass Micro-Stent; Alcon, Fort Worth, Texas, USA) implantation into the supraciliary space.
Main Outcome Measures:
Outcome measures included the occurrence of ocular adverse events, mean intraocular pressure (IOP) change, and glaucoma medication use through 12 months.
Results:
Mean baseline IOP was 22.5 ± 8.0 mm Hg and number of medications was 2.7 ± 1.0. The majority of patients had undergone either prior trabeculectomy or aqueous shunt surgery. There were no serious intraoperative complications or major adverse events following supraciliary stenting. The most common adverse events included transient hyphema (3/20, 15%), transient IOP > 30 mm Hg (4/20, 20%), and transient IOP < 6 mm Hg (4/20, 20%). At 12 months, mean IOP was 14.9 ± 4.3 mm Hg-a 33.7% reduction (P = .01). Mean medication usage decreased 56% to 1.2 ± 1.5 at 12 months (P = .01). Two patients (10%) required subsequent aqueous shunt insertion.
Conclusion:
Ab interno supraciliary stenting has a favorable safety profile and provides an effective approach to controlling IOP and reducing medication burden in eyes in which previous glaucoma surgery has failed.
More Related Videos
04:53A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
06:55Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
Related Concept Videos
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
Survey Safety
Glaucoma: Overview
Self-Efficacy
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment